New pages

From Bay Area Structural Heart Wiki
New pages
Hide registered users | Hide bots | Show redirects

9 December 2025

  • 22:4022:40, 9 December 2025 AveirInterrogation (hist | edit) [606 bytes] Rosenbzj (talk | contribs) (Created page with "-The Avier 5-lead is located below the St. Jude Programmer. It only works with the larger/older St. Jude Programmer. Prior to device interrogation/reprogramming: 1) Turn RF generator off 2) Turn Amp off 3) Turn magnet off (keep PIU on) Out of the two torso diagrams on the 5-lead box, use the one on the left (patient cable 3625) to place the leads. The Aveir Programmer will read N/A for 1-2 min after turning the magnet off if Amp & RF generator are already off, th...")

5 November 2025

17 October 2025

  • 16:0616:06, 17 October 2025 LoopWorkflow (hist | edit) [2,338 bytes] Rosenbzj (talk | contribs) (Created page with "ROUGH DRAFT: Loop Implant Procedure Workflow 1. Patient Identification and Pre-Procedure Check o Confirm patient’s full name and date of birth using two identifiers o Verify and document allergies o Verify procedure and consent form is signed and complete 2. Patient Preparation o Walk patient to ACU bathroom o Provide:  Hospital gown  Hair cover and shoe cover  Belongings bag for clothes and personal items o Instruct patent to:  Remove everything from the...")

13 October 2025

  • 16:2216:22, 13 October 2025 New ccl procedure (hist | edit) [368 bytes] Suddemj (talk | contribs) (Created page with "{| class="wikitable" ! colspan="4" |Valve in MAC with Antegrade Lampoon |- !Anesthesia !Imaging !Access !ACIST/manifold |- |General L Radial art line |Fluoro and TEE | *26F RFV (For transeptal equipment) (No need for E-Sheath) |One manifold with contrast |- ! colspan="4" |Pre-Procedure Watchouts |- | colspan="4" | PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN |- |}")

27 September 2025

  • 15:2715:27, 27 September 2025 TEE Protocol (hist | edit) [3,329 bytes] Suddemj (talk | contribs) (Created page with "{| class="wikitable" ! Sutter TEE Protocol !! !! !! |- | Setup || || || |- | Obtain height, weight, blood pressure on all patients || || || |- | Obtain ECG tracing; 3 beat loop; if HR >100 bpm increase #loops to 4, if greater than 120 bpm to 5 beats || || || |- | DO NOT ACQUIRE IMAGES WITHOUT AN ADEQUATE ECG TRACING || || || |- | View || Modality || Image || #beats |- | 1 Patient information page || || ||...") originally created as "Sutter TEE Protocol"
  • 15:2615:26, 27 September 2025 TTE Protocol Post MV TEER/ TMVI (hist | edit) [5,686 bytes] Suddemj (talk | contribs) (Created page with "{| class="wikitable" ! !! Sutter TTE Protocol Post MV TEER/ TMVI !! !! !! |- | || Setup || || || |- | || Obtain height, weight, blood pressure on all patients || || || |- | || Obtain ECG tracing; 3 beat loop; if HR >100 bpm increase #loops to 4, if greater than 120 bpm to 5 beats || || || |- | || DO NOT ACQUIRE IMAGES WSITHOUT AN ADEQUATE ECG TRACING || || || |- | || View || Modality || Image || #beats |- | || 1...") originally created as "Sutter TTE Protocol Post MV TEER/ TMVI"
  • 15:2315:23, 27 September 2025 TTE Protocol Post LAAO or PFO/ASD (hist | edit) [3,676 bytes] Suddemj (talk | contribs) (Created page with "{| class="wikitable" ! Sutter TTE Protocol Protocol Post LAAO or PFO/ASD !! !! !! |- | Setup || || || |- | Obtain height, weight, blood pressure on all patients || || || |- | Obtain ECG tracing; 3 beat loop; if HR >100 bpm increase #loops to 4, if greater than 120 bpm to 5 beats || || || |- | DO NOT ACQUIRE IMAGES WITHOUT AN ADEQUATE ECG TRACING || || || |- | View || Modality || Image || #beats |- | 1 Patient...") originally created as "Sutter TTE Protocol Protocol Post LAAO or PFO/ASD"
  • 15:2215:22, 27 September 2025 TTE Protocol Pre imaging & S/P TAVR assessment (hist | edit) [4,462 bytes] Suddemj (talk | contribs) (Created page with "{| class="wikitable" ! Sutter TTE Protocol Pre imaging & S/P TAVR assessment !! !! !! |- | Setup || || || |- | Obtain height, weight, blood pressure on all patients || || || |- | Obtain ECG tracing; 3 beat loop; if HR >100 bpm increase #loops to 4, if greater than 120 bpm to 5 beats || || || |- | DO NOT ACQUIRE IMAGES WITHOUT AN ADEQUATE ECG TRACING || || || |- | View || Modality || Image || #beats |- | 1 Pat...") originally created as "Sutter TTE Protocol Pre imaging & S/P TAVR assessment"

22 September 2025