Woods PVI

From Bay Area Structural Heart Wiki
Revision as of 00:32, 2 December 2023 by Rosenbzj (talk | contribs)

Check patient chart - If patient has a PPM/ICD, we'll use fluoro (pull a RadPad/Rampart Cover, bring appropriate programmer in room, notify anesthesia for abx.) If patient has any other implants, notify anesthesia for abx. If EF<40%, one of the 3 pressure lines (marked blue) will be transduced to sample LA pressure.

Pull List

Longs + other stuff from Sterile Core:

EP Pack, Sheet/Chuck/HoverMat, possible RadPad/Rampart Cover

LiveWire (DuoDeca)

8F AcuNav

Grid

Ablation (Determine TactiFlex vs. TactiCath)

Agilis Small Curl

Versacross Kit (make sure pigwire = 180cm, not 230, boxes are very similar)


(3) Yellow Filters

Ensite X Patch Kit (make sure it's not Ensite Precision)

Ablation Tubing

Grid Cable

DuoDeca Cable

Vascade x3



Stuff from Lab4 Pyxis:

US cover x2 (Linear/TTE)

Ice cover

8F Locking (for DuoDeca/ACT line)

8F Pinnacle (Agilis/Ablation)

8F Pinnacle (Versacross/Grid)

ACT Line

(3) Pressure Tubings (1 possibly w/Transducer depending on EF)


0-PDS

Needle Driver

Stopcock

Local


3 Ground Patches

4 sleeves of EKG dots

Defib Pads

SPO2 probe

Bair Hugger

BP Cuff