Woods PVI
Check patient chart -
If patient has a PPM/ICD, we'll use fluoro (pull a RadPad/Rampart Cover, bring appropriate programmer in room, lift rampart, notify anesthesia for abx.)
If patient has any other implants, notify anesthesia for abx.
If EF<40%, one of the 3 pressure lines (marked blue) will be transduced to sample LA pressure.
Pull List
Longs + other stuff from Sterile Core:
EP Pack, Sheet/Chuck/HoverMat, possible RadPad/Rampart Cover
LiveWire (DuoDeca)
8F AcuNav
Grid
Ablation (Determine TactiFlex vs. TactiCath)
Agilis Small Curl
Versacross Kit (make sure pigwire = 180cm, not 230, boxes are very similar)
(3) Yellow Filters
Ensite X Patch Kit (make sure it's not Ensite Precision)
Ablation Tubing
Grid Cable
DuoDeca Cable
Vascade x3
Stuff from Lab4 Pyxis:
US cover x2 (Linear/TTE)
Ice cover
8F Locking (for DuoDeca/ACT line)
8F Pinnacle (Agilis/Ablation)
8F Pinnacle (Versacross/Grid)
ACT Line
(3) Pressure Tubings (1 possibly w/Transducer depending on EF)
0-PDS
Needle Driver
Stopcock
Local
3 Ground Patches
4 sleeves of EKG dots
Defib Pads
SPO2 probe
Bair Hugger
BP Cuff
Prep Enso