David Daniels M.D.: Difference between revisions
From Bay Area Structural Heart Wiki
(→Notes:) |
(updated AS eval equipment when no Langston) |
||
Line 23: | Line 23: | ||
*Retrograde channel on McKesson in red. | *Retrograde channel on McKesson in red. | ||
*Left groin will have retrograde guide. | *Left groin will have retrograde guide. | ||
*Right groin will have antegrade guide | *Right groin will have antegrade guide | ||
Line 40: | Line 40: | ||
===R/L Heart for AS=== | ===R/L Heart for AS no Langston=== | ||
*Micropuncture | |||
*7F 90cm Shuttle Sheath | |||
*5F 125cm pigtail | |||
*6F 10cm pinnacle | |||
*2x manifold transducers | |||
**Dr. is OK with using a manifold for the case, no ACIST necessary | |||
*6fr. PA catheter | |||
*5F JL4/JR4 | |||
*Short straight stiff glidewire for valve crossing | |||
*5fr AL1 | |||
*Exchange length J wire | |||
===Radial with Eaucath=== | |||
*Eaucath | |||
*His blue angiocath | |||
*Micropuncture set | |||
*260 J-wire | |||
====Sequence==== | |||
#Access with angiocath | |||
#MP wire | |||
#MP sheath | |||
#Radial drugs | |||
#260J-wire | |||
#Eaucath | |||
<br /> | |||
===R/L Heart for AS with Langston=== | |||
*2x 5/6 slender radial sheaths with angiocath | *2x 5/6 slender radial sheaths with angiocath | ||
Line 65: | Line 101: | ||
#Exchange over long wire AL1 for Langston | #Exchange over long wire AL1 for Langston | ||
#Use standard transducers for accuracy, do not use ACIST | #Use standard transducers for accuracy, do not use ACIST | ||
<br /><hr /> | <br /><hr /> | ||
[[Category:Physicians]] | [[Category:Physicians]] |
Revision as of 22:10, 7 December 2020
Glove size | 7 |
---|---|
Access |
|
Radial Setup |
|
Radial Cocktail |
|
Groin Setup |
|
Closure Device |
|
Right Heart Setup |
|
Intervention Setup | |
Phone Number | 1-415-385-9243 |
Pager Number |
Notes:
CTO
- Preclose
- 8fr. x 45 Brite Tip sheath
- Assume bilateral groins
- ACIST and 3-port manifold
- Watchdogs
- Retrograde channel on McKesson in red.
- Left groin will have retrograde guide.
- Right groin will have antegrade guide
FFR
- Adenosine IC 10 mcg/ml concentration
Post Heart Transplant LHC/IVUS with DD
- 4/5 Glide Sheath
- 5F JR4 Diagnostic
- 5F EBU3.5
- Runthrough
- IVUS
R/L Heart for AS no Langston
- Micropuncture
- 7F 90cm Shuttle Sheath
- 5F 125cm pigtail
- 6F 10cm pinnacle
- 2x manifold transducers
- Dr. is OK with using a manifold for the case, no ACIST necessary
- 6fr. PA catheter
- 5F JL4/JR4
- Short straight stiff glidewire for valve crossing
- 5fr AL1
- Exchange length J wire
Radial with Eaucath
- Eaucath
- His blue angiocath
- Micropuncture set
- 260 J-wire
Sequence
- Access with angiocath
- MP wire
- MP sheath
- Radial drugs
- 260J-wire
- Eaucath
R/L Heart for AS with Langston
- 2x 5/6 slender radial sheaths with angiocath
- (Santa Rosa)1 7 Fr slender radial sheath with angiocath, 1 6 Fr Prelude sheath with stiff micropuncture set
- 2x manifold transducers
- Dr. is OK with using a manifold for the case, no ACIST necessary
- 6fr. PA catheter
- 5fr. Tig
- 7fr. Langston catheter
- Short straight stiff glidewire
- 5fr AL1
- Exchange length J wire
Sequence
- Access ultrasound guided vein
- Standard Radial access
- PA catheter for pressures
- Tig for cors
- Exchange over long wire Tig for AL1
- J out for Glidewire
- Cross valve
- Exchange over long wire AL1 for Langston
- Use standard transducers for accuracy, do not use ACIST