David Daniels M.D.

From Bay Area Structural Heart Wiki


Glove size 7 *CHECK DD's PROCEDURAL PLAN IN H&P FOR SUPPLIES
Access
  • U/s and micropuncture
Radial Setup
  • 4/5 angiocath dx only
  • 5/6 angiocath pci
  • Tig4
  • 260J
Radial Cocktail
  • 200 mcg NTG
  • 2.5mg Verapamil
  • 60u/kg Heparin
Groin Setup
  • 6fr sheath
  • 6Fr JL4 / JR4
Closure Device
  • Perclose
Right Heart Setup
  • Manifold
  • 6fr wedge cath
  • 5/6 slender angiocath
  • .035 wire
  • RN to put brachial IV in
  • Biopsy - Jaws ALWAYS
Intervention Setup
Phone Number 1-415-385-9243
Pager Number

Edit this page

Notes:

LHC for Renal Transplant

See Pre-Kidney Heart Cath

  • Femoral access
  • U/S probe cover
  • Micropuncture
  • 6frx10cm Pinnacle sheath
  • 6fr. JL4 guide
  • 6fr. JR4 guide
  • Runthrough
  • Co-Pilot
  • Wire introducer
  • .035x150 J
  • Perclose
  • ACIST setup
  • Biplane

Note Protip: Make sure arms and armboards are tucked-in as much as possible!

Sequence

  1. Access with Micropuncture and U/s.
  2. JL4 - trade out J-wire for Runthrough.
  3. Isocenter
  4. He will use Runthrough to confirm engagement.
  5. 4 for 6 on the ACIST, once he fills the guide note the contrast count. This is zero.
  6. Biplane to RAO/Cranial and LAO/Caudal
  7. Take the shot
  8. Exchange L4 for R4
  9. 2 for 3 on the ACIST
  10. Same as Left for engagement and contrast.
  11. Perclose

CTO

  • Preclose
  • 8fr. x 45 Brite Tip sheath
  • Assume bilateral groins
  • ACIST and 3-port manifold
  • Watchdogs
  • Retrograde channel on McKesson in red.
  • Left groin will have retrograde guide.
  • Right groin will have antegrade guide

FFR

  • Adenosine IC 10 mcg/ml concentration

Post Heart Transplant LHC/IVUS with DD

  • 4/5 Glide Sheath
  • 5F JR4 Diagnostic
  • 5F EBU3.5
  • Runthrough
  • IVUS

R/L Heart for AS no Langston

  • Micropuncture
  • 7F 70cm Shuttle Sheath or Ansel 70cm
  • 5F angled pigtail
  • 6F 10cm pinnacle
  • 2x manifold transducers
    • Dr. is OK with using a manifold for the case, no ACIST necessary
  • 6fr. PA catheter
  • 5F JL4/JR4
  • Short straight stiff glidewire for valve crossing
  • 5fr AL1
  • Exchange length J wire

Radial with Eaucath

  • Eaucath
  • His blue angiocath
  • Micropuncture set
  • 260 J-wire


Sequence

  1. Access with angiocath
  2. MP wire
  3. MP sheath
  4. Radial drugs
  5. 260J-wire
  6. Eaucath

R/L Heart for AS with Langston

  • 2x 5/6 slender radial sheaths with angiocath
    • (Santa Rosa)1 7 Fr slender radial sheath with angiocath, 1 6 Fr Prelude sheath with stiff micropuncture set
  • 2x manifold transducers
    • Dr. is OK with using a manifold for the case, no ACIST necessary
  • 6fr. PA catheter
  • 5fr. Tig
  • 7fr. Langston catheter
  • Short straight stiff glidewire
  • 5fr AL1
  • Exchange length J wire

Sequence

  1. Access ultrasound guided vein
  2. Standard Radial access
  3. PA catheter for pressures
  4. Tig for cors
  5. Exchange over long wire Tig for AL1
  6. J out for Glidewire
  7. Cross valve
  8. Exchange over long wire AL1 for Langston
  9. Use standard transducers for accuracy, do not use ACIST