(Created page with "{{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}} *Procedure will be done on table* ==Supplies== *Normal Saline 0.9% 1000 ml *Angio pack Turtle shell cover Fluoro drape Probe cover Pickups Suture (3.0 Vicryl) Biopatch Ioban Suction tubing 5-in-1-adapter Aspira Peritoneal Catheter (Red box -Pyxis outside Lab 3) Aspira Peritoneal home dressing kit (Blue box – Pyxis outside Lab 3)...")
 
No edit summary
Line 1: Line 1:
{{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}}
{{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}}


*Procedure will be done on table*
'''Procedure will be done on table'''
==Supplies==
==Supplies==
*Normal Saline 0.9% 1000 ml   
*Normal Saline 0.9% 1000 ml   

Revision as of 17:27, 23 October 2024

Note Note: Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure

Procedure will be done on table

Supplies

  • Normal Saline 0.9% 1000 ml
  • Angio pack

Turtle shell cover

Fluoro drape

Probe cover

Pickups

Suture (3.0 Vicryl)

Biopatch

Ioban

Suction tubing

5-in-1-adapter

Aspira Peritoneal Catheter (Red box -Pyxis outside Lab 3)

Aspira Peritoneal home dressing kit (Blue box – Pyxis outside Lab 3)


  • Have Neptune or suction canister ready for drainage*


BRONZO:

Dermabond

Will get access first, then tunnel towards the access


DARE:

Tunnel, retrograde after inserting

Cut the “Y” portion and attach tunneler. Keep stylet

3.0 & 4.0 Vicryl

Amplatz wire 180cm

RAJ:

None



BRITTANY:

Will get access first, then tunnel

3.0 Vicryl

Dermabond/Exofin


EVAN:




SAMIR:





LYNNE: