Aspira - Peritoneal: Difference between revisions
From Bay Area Structural Heart Wiki
(Created page with "{{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}} *Procedure will be done on table* ==Supplies== *Normal Saline 0.9% 1000 ml *Angio pack Turtle shell cover Fluoro drape Probe cover Pickups Suture (3.0 Vicryl) Biopatch Ioban Suction tubing 5-in-1-adapter Aspira Peritoneal Catheter (Red box -Pyxis outside Lab 3) Aspira Peritoneal home dressing kit (Blue box – Pyxis outside Lab 3)...") |
No edit summary |
||
Line 1: | Line 1: | ||
{{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}} | {{Note|Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure}} | ||
'''Procedure will be done on table''' | |||
==Supplies== | ==Supplies== | ||
*Normal Saline 0.9% 1000 ml | *Normal Saline 0.9% 1000 ml |
Revision as of 17:27, 23 October 2024
Note: Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure
Procedure will be done on table
Supplies
- Normal Saline 0.9% 1000 ml
- Angio pack
Turtle shell cover
Fluoro drape
Probe cover
Pickups
Suture (3.0 Vicryl)
Biopatch
Ioban
Suction tubing
5-in-1-adapter
Aspira Peritoneal Catheter (Red box -Pyxis outside Lab 3)
Aspira Peritoneal home dressing kit (Blue box – Pyxis outside Lab 3)
- Have Neptune or suction canister ready for drainage*
BRONZO:
Dermabond
Will get access first, then tunnel towards the access
DARE:
Tunnel, retrograde after inserting
Cut the “Y” portion and attach tunneler. Keep stylet
3.0 & 4.0 Vicryl
Amplatz wire 180cm
RAJ:
None
BRITTANY:
Will get access first, then tunnel
3.0 Vicryl
Dermabond/Exofin
EVAN:
SAMIR:
LYNNE: