Aspira - Peritoneal
From Bay Area Structural Heart Wiki
Note: Ultrasound patient first before opening catheter to confirm they have enough fluid for the procedure
Procedure will be done on table
Supplies
- Normal Saline 0.9% 1000 ml
- Angio pack
- Turtle shell cover
- Fluoro drape
- Probe cover
- Pickups
- Suture (3.0 Vicryl)
- Biopatch
- Ioban
- Suction tubing
- 5-in-1-adapter
- Aspira Peritoneal Catheter (Red box -Pyxis outside Lab 3)
- Aspira Peritoneal home dressing kit (Blue box – Pyxis outside Lab 3)
Protip: Have Neptune or suction canister ready for drainage
Bronzo
- Dermabond
- Will get access first, then tunnel towards the access
Dare
- Tunnel, retrograde after inserting
- Cut the “Y” portion and attach tunneler. Keep stylet.
- 3.0 & 4.0 Vicryl
- Amplatz wire 180cm
Brittany
- Will get access first, then tunnel
- 3.0 Vicryl
- Dermabond/Exofin