TAVI - CoreValve (Medtronic): Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
No edit summary
Line 30: Line 30:
*5Fr AL1 diagnostic
*5Fr AL1 diagnostic
*5Fr Ang Pigtail
*5Fr Ang Pigtail
*5Fr Str Pigtail
*5Fr JL4/JR4 (when doing coronary angiography)
*5Fr JL4/JR4 (when doing coronary angiography)
*5Fr Str Pigtail


===Medications on table:===
===Medications on table:===
Line 38: Line 38:


*Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)
*Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)
*10 ml Rotaglide


===Miscellaneous Supplies===
===Miscellaneous Supplies===

Revision as of 22:21, 31 October 2019

Transcatheter Aortic Valve Repair (Wikipedia) procedures utilize a femoral approach to deliver a stent-based aortic valve to the patients heart. There are two valve types available:

This procedure is usually done in Room 1, and requires a 5 person team: Front table scrub, Back table scrub (device prep), Circulator, Pacer/Circulator, and Recorder. The rep for the respective company will be present to assist with device prep except in the case of an emergency valve placement.

In rare cases, the BASILICA procedure will be necessary to split the existing valve leaflets to prevent blockage of the coronary arteries. In that situation, the equipment on the BASILICA page will be needed in addition to the equipment listed below.

Daniels/Spies - Draft

ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX

Sheaths:

  • 5Fr Micropunture Kit
  • 6Fr x 10cm sheath
  • 8Fr x 10 cm sheath (Dilator used only)
  • 8Fr x 35 cm Brite Tip Sheath
  • 9Fr x 10cm sheath

Wires

  • (2) Cordis 150J
  • Cordis 260J
  • Safari 2
  • Terumo Stiff Straight Glidewire 0.035 x 150 cm

Catheters:

  • 5Fr AL1 diagnostic
  • 5Fr Ang Pigtail
  • 5Fr Str Pigtail
  • 5Fr JL4/JR4 (when doing coronary angiography)

Medications on table:

  • Lido/Bupivicaine 50/50
  • Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)

Miscellaneous Supplies

  • Daniel’s TAVR 3-port manifold kit
  • Acist hand control
  • 25g 1 ½ “ Daniels Lido Needle"
  • Suture Lock
  • 2L cold saline
  • ¾ sterile sheet or back table cover
  • 20 ml syringe
  • (3) Perclose
  • Coons 18fr. Dilator

Transvenous pacemaker supplies

  • 5Fr Josephson Pacing catheter
  • Dual Red/Black Pacing Remington cables
  • EP Quad Cable

Standby ECMO & Pericardial Effusion supplies

EMERGENT PERICARDIOCENTESIS

Not DD or CS

Call Echo

  • Micropuncture
  • 75 Amplatz SS
  • Pericardiocentesis tray
  • Accordion drain bag

Spies

Call Echo

Supplies:

  • Micro puncture
  • 150cm J wire
  • 4/5fr slender sheath
  • 5fr straight pigtail diagnostic
  • gravity drainage bag
  • brown reservoir lab canister
  • Two 50 or 60ml syringes


Daniels

Call Echo

Supplies

Open

Emergency Kit located in each lab containing the following items:

  • Eye drape
  • Skater introducer set
  • Bard locking pigtail (6f or 8f)
  • (3) 60ml luer lock syringe
  • Amplatz super stiff .035 180cm wire
  • Probe cover
  • Stopcock
  • Accordion drainage bag

Standby

  • Chiba biopsy needle 10cm 18g
  • Standard .035 150cm j wire



Approved: MM/YY