David Daniels M.D.: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 34: | Line 34: | ||
*2x 5/6 slender radial sheaths with angiocath | *2x 5/6 slender radial sheaths with angiocath | ||
*2x manifold transducers | *2x manifold transducers | ||
**Dr. is OK with using a manifold for the case, no ACIST necessary | |||
*6fr. PA catheter | *6fr. PA catheter | ||
*5fr. Tig | *5fr. Tig | ||
Line 53: | Line 54: | ||
#Use standard transducers for accuracy, do not use ACIST | #Use standard transducers for accuracy, do not use ACIST | ||
<br /><hr /> | <br /><hr /> | ||
[[Category:Physicians]] | [[Category:Physicians]] |
Revision as of 15:43, 20 April 2020
Glove size | 7 |
---|---|
Access |
|
Radial Setup |
|
Radial Cocktail |
|
Groin Setup |
|
Closure Device |
|
Right Heart Setup |
|
Intervention Setup | |
Phone Number | 1-415-385-9243 |
Pager Number |
Notes:
CTO
- Preclose
- 8fr. x 45 Brite Tip sheath
- Assume bilateral groins
- ACIST and 3-port manifold
- Watchdogs
FFR
- Adenosine IC 100mcg/ml concentration
Post Heart Transplant LHC/IVUS with DD
- 4/5 Glide Sheath
- 5F JR4 Diagnostic
- 5F EBU3.5
- Runthrough
- IVUS
R/L Heart for AS
- 2x 5/6 slender radial sheaths with angiocath
- 2x manifold transducers
- Dr. is OK with using a manifold for the case, no ACIST necessary
- 6fr. PA catheter
- 5fr. Tig
- Langston catheter
- Short straight stiff glidewire
- 5fr AL1
- Exchange length J wire
Sequence
- Access ultrasound guided vein
- Standard Radial access
- PA catheter for pressures
- Tig for cors
- Exchange over long wire Tig for AL1
- J out for Glidewire
- Cross valve
- Exchange over long wire AL1 for Langston
- Use standard transducers for accuracy, do not use ACIST