set fluoro to card alt 10p/s
drugs - verapamil, lido+epi, 1L of hep saline for the table, normal manifold setup
To Drop:
preclose
straight 6 pig
33cm 20f gore (2cc saline to prep valve)
Grandslam 300cm
260cm 0.035" J
Amplatz 260cm 1cm floppy tip
VersaCross 260cm
TrueSteer (poss 13f Agilis instead, Ono thru Truesteer was tight though case was successful)
Raptor
Ono
50/60cc syringe
1L of hep saline on the table
manifold + pressure line
sentinel
5/6 slender radial sheath
2.5 of verapamil (instead of slurry for Spies)
Tegaderm for radial sheath
Radial drape
tr band
Procedural order:
1) radial access
2) verapamil
3) pigtail + wire to arch
4) arch picture thru pigtail (hand inject w/manifold)
5) grandslam
6) sentinel
7) rfv micro access + preclose + dilate
8) gore 20f (2cc saline in valve to prep) + versacross telescoping to transeptal
9) upsize versacross to either truesteer or agilis 13f (truesteer was tight interacting w/ono last case)
10) ono
11) raptor
12) retrieve
13) arch shot post sentinel removal
poss reimplant
tr band (12cc, green dot on sheath entry site) /groin closure