MAC Lampoon steps
From Bay Area Structural Heart Wiki
- RRA access -> 6fr slender
- Grandslam to check access to arch
- Grandslam removed until access is completed
- LFA access -> 8fr dilator -> Pre-close -> 8fr. Pinnacle
- LFV access -> 8.5fr. X 23 brite tip
- RFV access -> 8fr dilator -> Pre-close x2 -> Amplatz Super Stiff -> 26 Dry Seal
- 6fr pigtail through LFA for arch shot
- 6 FPS and subtraction
- Grandslam loaded in Sentinel and inserted
- Pigtail removed after Sentinel deployed
- .032x260 loaded in SL1 and advanced through Dryseal
- Wire removed and Baylis needle advanced
- Transseptal puncture
- If septum is soft/thin:
- SL1 advanced into LA
- .032x260 x2 inserted into LA via SL1
- If septum is thick/tough:
- .032x260 inserted into SL1 with MPA and placed in LUPV
- .032 exchanged for Amplatz SS 1cm
- SL1 advanced into LA
- Amplatz SS exchanged for .032x260 x2 inserted into LA
- SL1 removed
- Agilis x2 advanced into LA
- 6fr. PA loaded with Runthrough inserted into Agilis
- 6fr JR4 guide loaded with .035x150 inserted into 8fr LFA sheath
- Wire removed and Gooseneck inserted into JR4
- Runthrough snared in AO
- Runthrough externalized
- PA catheter removed
- 6fr. JL3.5 advanced over Runthrough
- Second 6fr JR4 with J-wire advanced through second Agilis
- Wire removed and Lampoon system advanced
- Gooseneck snare inserted into JL3.5
- IF ballooning leaflet for “Keyhole” technique make sure to keep wire straight until after ballooning
- Leaflet traversed
- Bovie settings: 30 cut to test and 70 cut for traversal and laceration
- Snare Astato wire
- Runthrough and Arterial guide removed
- Pacer inserted
- Balloon pump inserted
- Leaflet lacerated
- Guides and Lampoon System removed
- Have one Agilis, SL1 and .032 wire ready to re-cross septum
- Safari loaded in Pigtail and advanged to LV
- Pigtail removed
- Septostomy
- Valve inserted and deployed
- Pigtail used to remove Safari
- If a post deployment gradient is needed, balloon pump will be removed and short 8F sheath exchanged for 8F 90cm shuttle sheath. 125cm pigtail inserted to LV. 2nd manifold needed.