Paravalvular leak- Mitral

From Bay Area Structural Heart Wiki
Revision as of 01:42, 18 December 2020 by Warneh (talk | contribs)

Various equipment needed is dependent upon size of leak.

All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.


Total Length of FlexCath: 81cm.

Total Length of Agilis: 71cm

****If Flexcath is an acceptable option, use it. Much cheaper than agilis.*****

AVPII cable length: 100cm


90cm Shuttle Sheath is not long enough to put into FlexCath. Will have to remove flex cath.

Sheaths:

Open

  • 8F pinnacle
  • 5F Pinnacle (for shuttle sheath not for access)
  • 20F Dryseal
  • 110cm Shuttle sheaths

Standby

  • FlexCath
  • Agilis- small curve
  • 4fr x 10cm Pinnacle - (A-line)
  • Cook 30cm

Wires:

Open

  • 150J
  • 260J
  • Glide Advantage 260cm
  • Amplatz ES 260cm
  • .032 260J

Catheters:

Open

  • 5F MPA 125cm
  • 5fr angled pigtail
  • 180* torqvue (French size not important here, only using for the cable.)

Standby

  • 5fr IM diagnostic
  • 5fr JR4 diagnostic
  • Berenstein 125cm (Spies)

Transseptal

Open

  • Baylis machine
  • Baylis cable
  • Grounding pad
  • Large curve C1 Baylis needle
  • 8.5fr SL1 transseptal sheath

Misc Supplies:

Open

  • 0-Ethibond
  • Micropuncture
  • Perclose x 2
  • 3-port manifold naked (no ACIST)
  • 60cc syringe

Standby

  • Watchdog
  • stopcock

Device embolization / retrieval:

Standby

  • EnSnare or Gooseneck
  • 16 or 18fr x 33cm Dryseal
  • JR4 Guide