TAVI-JenaValve

From Bay Area Structural Heart Wiki
Revision as of 00:41, 26 June 2020 by Dronsfj (talk | contribs) (brain dump. more to come.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


Daniels/Spies - Draft[edit | edit source]

ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX

Sheaths:[edit | edit source]

  • 5Fr Micropunture Kit
  • 6Fr x 10cm sheath
  • 8Fr x 10 cm sheath (Dilator used only)
  • 8Fr x 35 cm Brite Tip Sheath
  • 9Fr x 10cm sheath
  • 18F Cook Sheath

Wires[edit | edit source]

  • (2) Cordis 150J
  • Cordis 260J
  • Safari 2

Catheters:[edit | edit source]

  • 5Fr MPA
  • 5Fr MPB
  • 5Fr Angled Pigtail

Medications on table:[edit | edit source]

  • Lido/Bupivicaine 50/50
  • Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)

Miscellaneous Supplies[edit | edit source]

  • 3-port manifold kit
  • Acist hand control
  • 2L cold saline
  • 2L room temp saline
  • (2) 60ml syringes
  • (2) 20ml syringes
  • stopcock
  • co-pilot
  • 108cm tubing
  • 500ml hep saline on pressure bag
  • back table cover
  • (3) Perclose
  • (5) bowls

Transvenous pacemaker supplies[edit | edit source]

  • 5Fr Josephson Pacing catheter
  • Dual Red/Black Pacing Remington cables
  • EP Quad Cable

PROCEDURAL INFO: