BASILICA
From Bay Area Structural Heart Wiki
(Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction)
Open
- 14frx33cm Gore Dry Seal Flex
- 6fr MP1 guide catheter
- .018 Platinum Plus guidewire 260 cm
- Gooseneck Snare 20mm
- 6 Fr PAL 1.0 (for LCA BASILICA) -OR- 6 FR MPA1 Guide (For RCA BASILICA)
- .014 Astato xs 20 guidewire 300 cm
- Bovie pen
- Grounding Pad
- Bovie machine
- (2) Watchdog devices
- (2) Stopcocks
- 4 hemostats
Standby
- Gooseneck snares 25, 30mm
- Piggyback wire converter 4fr x 145 (On standby)
- .035 QuickCross (On standby)
- AL2, AL3, EBU4, EBU 3.75 (Left leaflet)
- PAR1, JR4, IM, AR1 (Right leaflet)
- (3) .014 torque devices
- (2) .035 torque devices
- Finecross 135
Approved: MM/YY