BASILICA

From Bay Area Structural Heart Wiki
Revision as of 16:43, 21 October 2019 by Suddemj (talk | contribs)

BASILICA

(Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction)

ACC.org BASILICA Page

Open

  • 14frx33cm Gore Dry Seal Flex
  • 6fr MP1 guide catheter with Tuohy Borst and stop cock on the side
  • .018 Platinum Plus guidewire 260 cm
  • Gooseneck Snare 20mm
  • 6 Fr PAL 1.0 (for LCA BASILICA) or 6 FR MPA1 Guide (For RCA BASILICA)
  • Piggyback wire converter 4fr x 145
  • .014 Astato guidewire 300 cm


Misc. Supplies

  • Bovie pen
  • (2) Watchdog devices
  • (2) Stopcocks
  • 4 hemostats

Standby

  • Gooseneck snares 25, 30mm
  • AL2, AL3, EBU4, EBU 3.75 (Left leaflet)
  • PAR 1.0 JR4, IM, AR1 (Right leaflet)
  • (3) .014 torque devices
  • (2) .035 torque devices
  • Finecross 135
  • Extra Piggyback converters



Approved: MM/YY