Carotid TAVI

From Bay Area Structural Heart Wiki
Revision as of 00:31, 19 September 2020 by Dronsfj (talk | contribs)

Procedure to be performed in Hybrid OR 14 in conjunction with the OR team.


***TIMEOUT REMINDERS***

  • Transcutaneous O2 Sat
  • MAP above 100

Equipment

In addition to standard TAVR equipment the OR team will need:

  • Micropuncture
  • 6F 10cm Pinnacle Sheath


  • Safari wire instead of Amplatz ES
  • Can get away with 1 short J wire


Setup- Right Sided Carotid

  • Anesthesia to get left sided A line
  • Table at 30 degrees
  • Bring C arm in perpendicular to table
  • Echo at head of bed (TEE)
  • OR will do prep. (Include groins and right wrist)
  • First assist to stand at head of bed on the left
  • CT surgeon on right side with scrub RN
  • Cath Lab will have standard 2 tables plus high table for valve delivery.
    • mayo stand to bridge the gap between valve table and access site
  • Cover Fluoro Pedal and Base of C-arm
  • 2 venous extensions needed for Anesthesia
  • Leave large boom to the side of the room. Use Monitors 3 &4 for pigtail and pacer.
    • 3 Live and 4 McKesson
  • When DD moves to the head to assist with valve crossing bring in monitors 3 &4
    • 3- echo 4-Mckesson 1- Live 2- Anesthesia Vitals
    • Right wall monitor with quad view
    • boom with standard tavr display


Procedure- Right Sided

  • Sheridan will start with cutdown.
  • DD will obtain radial access for pigtail and femoral venous for Pacer
  • AOgram per usual
  • CTS inserts 6F sheath
  • One CL tech stays at foot of bed for injections and pigtail pull
  • Preloaded AL1 and Stiff glide inserted
  • stiff glide exchanged for SAFARI
  • E sheath inserted
  • Valve delivered
  • Venous sheath removed and figure 8 with prolene
  • TR Band applied after OR finished closing.