Revision as of 20:25, 27 March 2020
Procedure to lacerate the Mitral valve leaflet to clear LVOT obstruction in the setting of TMVR.
This equipment list should be considered as add-on equipment to a TMVR procedure. It is not a complete procedure list!
Contrast use is unlikely for valve in valve and valve in ring variants.
- Astato 300cm
- Amplatz Super Stiff 1cm tip
- Piggyback converter catheter
- Runthrough 300
- Bovie Pen
- 2 - Touhy-Borst
- 2 - Regular stopcock
- 2 - 12” Extension
- 2 - 60cc syringe
- 2 - .014 torque device
- 18 x 30 En-Snare
- Agilis (Ask before opening)
- 6fr balloon wedge catheter
- (2) 7fr JL3.5 guide
- Langston Pigtail
- 6fr. MPA diagnostic
- 6fr. X 10cm Pinnacle
- 14fr. Dry Seal
- 12,14,16 mm x 40 balloons (Ask for size) Mustang or XXL balloons
Standby
- 7fr JR4 guide