Sheaths:

Open

  • 7fr x 10cm Pinnacle??
  • 8F pinnacle

Standby

  • 4fr x 10cm Pinnacle - (A-line)
  • Dryseal
  • Shuttle Sheaths (90cm and 110cm)


Wires:

Open

  • 150J
  • 260J
  • Glide Advantage
  • Amplatz ES

Standby

  • Straight Glidewire 260
  • Safari 2
  • Confida
  • Roadrunner (Spies)


Catheters:

Open

  • 6fr MPA 125cm diagnostic
  • 5fr angled pigtail

Standby

  • Agilis
  • 5fr IM diagnostic
  • 5fr JR4 diagnostic
  • Berenstein 125cm (Spies)


Transseptal (Only for Mitral):

Open

  • Baylis machine
  • Baylis cable
  • Grounding pad
  • Large curve C1 Baylis needle
  • 8.5fr SL1 transseptal sheath


Misc Supplies:

Open

  • Probe cover
  • Micropuncture
  • (2) Perclose
  • 3-port manifold (no ACIST)
  • 60cc syringe

Standby

  • Watchdog


Device embolization / retrieval:

Standby

  • EnSnare or Gooseneck
  • Dryseal