Paravalvular leak: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
=Daniels / Spies / Walsh - Draft= | =Daniels / Spies / Walsh - Draft= | ||
== Mitral == | ==Mitral== | ||
=== Sheaths: === | ===Sheaths:=== | ||
==== Open ==== | ====Open==== | ||
* 7fr x 10cm Pinnacle | *7fr x 10cm Pinnacle | ||
* 12 or 14fr Dryseal | *12 or 14fr Dryseal | ||
* 8.5 SL1 | *8.5 SL1 | ||
==== Standby ==== | ====Standby==== | ||
* 4fr x 10cm Pinnacle - A-line | *4fr x 10cm Pinnacle - (A-line) | ||
<br /> | <br /> | ||
=== Wires: === | ===Wires:=== | ||
==== Open ==== | ====Open==== | ||
* Cordis 150J | *Cordis 150J | ||
* Stiff angled Glidewire 260 | *Stiff angled Glidewire 260 | ||
* Supracore 190 | *Supracore 190 | ||
==== Standby ==== | ====Standby==== | ||
* Straight Glidewire 260 | *Straight Glidewire 260 | ||
* Amplatz Extra Stiff 180 and 260 | *Amplatz Extra Stiff 180 and 260 | ||
* Safari 2 | *Safari 2 | ||
* Confida | *Confida | ||
* .032 x 150J (Backup for SL1 wire) | *.032 x 150J (Backup for SL1 wire) | ||
* Roadrunner (Spies) | *Roadrunner (Spies) | ||
<br /> | <br /> | ||
=== Catheters: === | ===Catheters:=== | ||
==== Open ==== | ====Open==== | ||
* 6fr MPA '''125cm''' diagnostic | *6fr MPA '''125cm''' diagnostic | ||
* 5fr angled pigtail | *5fr angled pigtail | ||
* 7fr MP guide | *7fr MP guide | ||
==== Standby ==== | ====Standby==== | ||
* Small and medium curve Agilis | *Small and medium curve Agilis | ||
* 5fr IM diagnostic | *5fr IM diagnostic | ||
* 5fr JR4 diagnostic | *5fr JR4 diagnostic | ||
* Berenstein 125cm (Spies) | *Berenstein 125cm (Spies) | ||
<br /> | <br /> | ||
=== Baylis Transseptal: === | ===Baylis Transseptal:=== | ||
==== Open ==== | ====Open==== | ||
* Baylis machine | *Baylis machine | ||
* Baylis cable | *Baylis cable | ||
* Grounding pad | *Grounding pad | ||
* Large curve C1 Baylis needle | *Large curve C1 Baylis needle | ||
<br /> | <br /> | ||
=== Misc Supplies: === | ===Misc Supplies:=== | ||
====Open==== | |||
*Probe cover | |||
*Micropuncture | |||
*(2) Perclose | |||
*3-port manifold (no ACIST) | |||
*60cc syringe | |||
====Standby==== | |||
*Co-Pilot | |||
*Watchdog | |||
<br /> | |||
===Devices:=== | |||
==== Standby ==== | ====Standby==== | ||
* | *Amplatzer II Plug (Hamburger) | ||
* | *Amplatzer 4 Plug (Hersheys kiss) | ||
*Amplatzer Duct Occluder (ADO2) | |||
*Amplatzer TorqVue Delivery system | |||
<br /> | <br /> | ||
=== | === Device embolization / retrieval: === | ||
==== Standby ==== | ==== Standby ==== | ||
* | * 6 or 7fr. EnSnare or Gooseneck | ||
* | * 16 or 18fr x 33cm Dryseal | ||
<HR /> | <br /> | ||
=== Pericardiocentesis standby: === | |||
{{Pericardiocentesis}}<HR /> | |||
Approved: MM/YY | Approved: MM/YY | ||
[[Category:Procedures]] | [[Category:Procedures]] |
Revision as of 19:14, 17 October 2019
Daniels / Spies / Walsh - Draft
Mitral
Sheaths:
Open
- 7fr x 10cm Pinnacle
- 12 or 14fr Dryseal
- 8.5 SL1
Standby
- 4fr x 10cm Pinnacle - (A-line)
Wires:
Open
- Cordis 150J
- Stiff angled Glidewire 260
- Supracore 190
Standby
- Straight Glidewire 260
- Amplatz Extra Stiff 180 and 260
- Safari 2
- Confida
- .032 x 150J (Backup for SL1 wire)
- Roadrunner (Spies)
Catheters:
Open
- 6fr MPA 125cm diagnostic
- 5fr angled pigtail
- 7fr MP guide
Standby
- Small and medium curve Agilis
- 5fr IM diagnostic
- 5fr JR4 diagnostic
- Berenstein 125cm (Spies)
Baylis Transseptal:
Open
- Baylis machine
- Baylis cable
- Grounding pad
- Large curve C1 Baylis needle
Misc Supplies:
Open
- Probe cover
- Micropuncture
- (2) Perclose
- 3-port manifold (no ACIST)
- 60cc syringe
Standby
- Co-Pilot
- Watchdog
Devices:
Standby
- Amplatzer II Plug (Hamburger)
- Amplatzer 4 Plug (Hersheys kiss)
- Amplatzer Duct Occluder (ADO2)
- Amplatzer TorqVue Delivery system
Device embolization / retrieval:
Standby
- 6 or 7fr. EnSnare or Gooseneck
- 16 or 18fr x 33cm Dryseal
Pericardiocentesis standby:
Not DD or CS
Call Echo
- Micropuncture
- 75 Amplatz SS
- Pericardiocentesis tray
- Accordion drain bag
Spies
Call Echo
Supplies:
- Micro puncture
- 150cm J wire
- 4/5fr slender sheath
- 5fr straight pigtail diagnostic
- gravity drainage bag
- brown reservoir lab canister
- Two 50 or 60ml syringes
Daniels
Call Echo
Supplies
Open
Emergency Kit located in each lab containing the following items:
- Eye drape
- Skater introducer set
- Bard locking pigtail (6f or 8f)
- (3) 60ml luer lock syringe
- Amplatz super stiff .035 180cm wire
- Probe cover
- Stopcock
- Accordion drainage bag
Standby
- Chiba biopsy needle 10cm 18g
- Standard .035 150cm j wire
Approved: MM/YY