== Mitral Valvuloplasty - DRAFT ==
==Mitral Valvuloplasty - DRAFT==
<br />
 
=== Sheaths: ===
 
==== Open ====
 
* 9frx20 Brite tip
* 8frx10 Pinnacle
* 8.5 SL1 transseptal
 
<br />
 
=== Wires: ===
 
==== Open ====
 
* Amplatz Super Stiff 260cm 1cm tip
* Cordis 150J
 
==== Standby ====
 
* .032 wire for SL1 sheath
 
<br />
 
=== Catheters: ===
 
==== Open ====
 
* 5fr MPA2
 
<br />
 
=== Misc Supplies: ===
 
==== Open ====
 
* Micropuncture
* US probe cover
* (2) 3-port manifolds
* Perclose
*
 
 
(Toray INOUE - Balloon)
(Toray INOUE - Balloon)



Revision as of 16:01, 14 October 2019

Mitral Valvuloplasty - DRAFT


Sheaths:

Open

  • 9frx20 Brite tip
  • 8frx10 Pinnacle
  • 8.5 SL1 transseptal


Wires:

Open

  • Amplatz Super Stiff 260cm 1cm tip
  • Cordis 150J

Standby

  • .032 wire for SL1 sheath


Catheters:

Open

  • 5fr MPA2


Misc Supplies:

Open

  • Micropuncture
  • US probe cover
  • (2) 3-port manifolds
  • Perclose


(Toray INOUE - Balloon)

1 RFV Access. X2

Conscious sedation by RN

TTE and ICE guidance (need sonographer)

Prerequisite: TEE done in Echo lab morning of to exclude LAA thrombus

Sheaths: •1 Probe Cover •1 5Fr VS Micropuncture Kit •1 9 Fr x >20 cm sheath RFV access •1 8 Fr Short sheath •1 8.5 Fr SL 1 transseptal sheath


Closure: •1 6Fr Perclose •1 Extra sterile mosquitos for Perclose


2 Manifold Set Up: No ACIST •2 3-port manifold



Wires: •1 cm Straight Tip Amplatz Super Stiff 260 cm


•Cordis “J” Wire 0.035 x 150 cm



Standby Items: •


Catheters: •1 5Fr. Multipurpose catheter


•1 5 Fr Arrow Swan


Standby Items: •


Transeptal Access Supplies •Large Curve C1 71cm Baylis Trans-septal Needle


•Baylis Cable


•Baylis Machine


•Orange Grounding Pad



Device Table •1 Toray INOUE-Balloon Kit (usually 28 mm, but need 26 and 30 mm available)


•2 1L bag Heparinized Saline (Both on pressured bag hanging on IV pole)


•1 Large Sterile Bowl filled with 1L Heparinized Saline for device use only


•2 60 ml luer-lock syringe


•5 High-Pressure stopcock


•50 ml Visipaque contrast for balloon prep. RATIO 1:5



Emergency Pericardiocentesis Supplies •Pericardiocentesis Tray


•Pericardiocentesis Supplies:


•5Fr VS Micropuncture


•Dilators


•0.035 J Wire 150 cm


•60 ml syringe


•Pericardiocenteis drainage bag


•Bard Pigtail drainage catheter size per MD request


Emergency Plug Dislodgement/Retrieval Supplies •NA


•IABP is device of choice for complication of severe mitral regurgitation



APPROVED: MD initials MM/YY