===THORACIC EVAR=== (one access)  
===Thoracic EVAR (one access) ===
*Micro puncture kit  
*Micro puncture kit  
*Berenstein 100cm  
*Berenstein 100cm  

Revision as of 19:42, 6 November 2024

  • INJECTOR SETUP: 1.0 SEC INJECTION DELAY (ALWAYS). 100% Contrast
  • Contrast Hand Injection 50/50
  • Heparinized Saline 1000 ml

Supplies

Open

  • Angio pack
  • Probe Cover
  • (2) Micro puncture Kit
  • (2) 7Fr Sheath 11cm
  • Fluoro Drape
  • Injector Syringe
  • Injector Tubing
  • Contrast
  • 60cc Luerlock Syringe (for balloon inflation)
  • Marking Pigtail Catheter
  • Bernstein 65cm
  • (4) Perclose (AAA)


Nathanson

  • (2) Stiff Glide wire 180cm (for access)
  • (2) Lunderquist wire
  • (2) Morse Syringe for Contrast
  • Morse syringe (for Lidocaine)
  • (2) K50 tubing's connected for contrast


Hong

  • (2) Glidewire Advantage 260cm
  • 20cc syringes for contrast
  • 35cc syringes for flush


Kaspar

  • (2) Stiff Glide wire 180cm (for access)
  • (2) Lunderquist wire
  • 3-way stopcock attach to injector tubing


Thoracic EVAR (one access)

  • Micro puncture kit
  • Berenstein 100cm
  • Marking Pigtail
  • (2) Perclose
  • 7Fr sheath 11cm
  • Double curve Lunderquist wire (Thoracic)


OR Surgical Table

  • Rubber shods (“Mosquito hemostats with yellow booties”)
  • (2) Wet White Towels
  • Sterile marking pen (OR)



Gore Rep

  • Stent Graft
  • Dryseal
  • Balloon


Standby

  • Bernstein 100cm
  • RIM
  • Stiff Glidewire 260cm
  • Glidewire 260cm
  • Torque device
  • Amplatzer Plug 10, 12
  • SOS 2 100cm
  • Coda Balloon
  • Snare
  • Inflation device