Globe Trial: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
Fluids: | |||
(4) 1L bags of NS, each with 5000u Heparin - 2 onto the scrub table, 2 for flush lines to the LA. | (4) 1L bags of NS, each with 5000u Heparin - 2 onto the scrub table, 2 for flush lines to the LA. | ||
Line 5: | Line 5: | ||
Lido/Bup | Lido/Bup | ||
Equipment droplist: | |||
2 scrub tables - each with an EP pack. One table will be for the device + introducer prep, the other for draping/access/transeptal/etc. | 2 scrub tables - each with an EP pack. One table will be for the device + introducer prep, the other for draping/access/transeptal/etc. |
Revision as of 03:11, 12 December 2023
Fluids:
(4) 1L bags of NS, each with 5000u Heparin - 2 onto the scrub table, 2 for flush lines to the LA.
Lido/Bup
Equipment droplist:
2 scrub tables - each with an EP pack. One table will be for the device + introducer prep, the other for draping/access/transeptal/etc.
Rampart + Radpad
2x yellow filters
10f acunav (non-soundstar)
Livewire Duodeca (no cable needed)
long versacross kit - 230cm pigwire
2x percloses (orthogonal preclose - 10&2)
Coonz Dilator (20f short from cart in sterile core)
2x Ice sleeve (1 for ice, 1 for duo deca which connects to Kardium's nonsterile proprietary CS cable)
2x Access sleeve (tte/linear)
ACT line
2x pressure lines (possibly 3? to extend ACT far enough)
Ioban
8F pinnacle (RFV - preclose + dilate + upsize to globe introducer - globe)
8f locking sheath (LFV - duodeca)
10.5 fastcath (LFV - ice)
3x 50cc syringe
driver/0pds/stopcock for woggle for left sided sheaths.
this page is a work in progress. created 12/11/23 zr