Aveir: Difference between revisions
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.) | -MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.) | ||
-1L heparinized saline on the scrub table | -1L heparinized saline (10,000u heparin) on the scrub table | ||
-50cc omnipaque or | -50cc omnipaque or visipaque if indicated (can be cut to ~50/50) | ||
- | -lidocaine/bupivicaine | ||
'''<big>Tech:</big>''' | '''<big>Tech:</big>''' |
Revision as of 19:47, 29 March 2023
RN:
-2x 1L bags NS with 2000u heparin per liter bag. One bag on gravity (these 2 lines will be labeled A/B), one on pressure (these 2 lines will be labeled C/D). 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then immediately come off pressure after they're flushed, as gravity is required per protocol.
-double label each line - one on roller clamp and one on the end where you attach to the extension.
-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.)
-1L heparinized saline (10,000u heparin) on the scrub table
-50cc omnipaque or visipaque if indicated (can be cut to ~50/50)
-lidocaine/bupivicaine
Tech:
-4x pressure tubing (labeled A, B, C, D)
-50-60cc syringe
-micropuncture + 8fr pinnacle (or 8f dilator)
-7cm floppytip 180cm amplatz xtra stiff
-dilators 12/18/24 short cooks
-0.0 PDS + needle driver
created 03/29/23 zr