TMVI: Difference between revisions
From Bay Area Structural Heart Wiki
(pasted from JD's email) |
No edit summary |
||
Line 1: | Line 1: | ||
Daniels | |||
Transcather Mitral Valve Replacement | |||
'''GENERAL ANESTHESIA | '''GENERAL ANESTHESIA AND TEE IMAGING''' | ||
'''ACCESS 2 FEMORAL VEINS ( | '''ACCESS 2 FEMORAL VEINS (TAVR AND PACER), 1 FEMORAL ARTERY (ANESTESIA)''' | ||
''' | '''PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN''' | ||
= SHEATHS: = | = SHEATHS: = | ||
* (1) 5F MICROPUNCTURE KIT | * (1) 5F MICROPUNCTURE KIT | ||
* (1) | * (1) 5F 10CM SHEATH | ||
*** '''OR''' 6F IF CORONARY IMAGING NECESSARY | |||
* (1) 8F 10CM SHEATH | * (1) 8F 10CM SHEATH | ||
* (1) 8F 35CM BRITE TIP SHEATH | * (1) 8F 35CM BRITE TIP SHEATH | ||
* (1) 9F 10CM SHEATH | * (1) 9F 10CM SHEATH | ||
* (1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH | * (1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH | ||
* (1) 8.5F AGILIS SMALL CURL | |||
= WIRES: = | = WIRES: = | ||
Line 25: | Line 25: | ||
* (2) .035 150CM J WIRE | * (2) .035 150CM J WIRE | ||
* (1) SAFARI 2 WIRE | * (1) SAFARI 2 WIRE | ||
== '''Standby''' == | == '''Standby''' == | ||
* | * .035 260CM J WIRE | ||
* AMPLATZ SUPER STIFF 1CM TIP | |||
* SUPRACORE 190CM | |||
= CATHETERS = | = CATHETERS = | ||
Line 38: | Line 38: | ||
* 6F STRAIGHT PIGTAIL 110CM | * 6F STRAIGHT PIGTAIL 110CM | ||
== '''Standby''' == | == '''Standby''' == | ||
* 6F | * 6F LANGSTON | ||
* 5.2F ANGLED PIGTAIL | |||
* 5F MPA | |||
* 5F JL4 AND JR4 (FOR CORONARIES) | |||
= PACING = | = PACING = | ||
Line 54: | Line 55: | ||
= VALVE TABLE = | = VALVE TABLE = | ||
* ( | * (4) STERILE BOWLS (2- 0.9% SALINE, 1-HEP SALINE, 1-15% CONTRAST MIX) | ||
* (1) 90 INCH DRAPE | * (1) 90 INCH DRAPE (OR) | ||
* 1L NORMAL SALINE IRRIGATION | * 1L NORMAL SALINE IRRIGATION | ||
* 500ML HEPARINIZED SALINE | * 500ML HEPARINIZED SALINE | ||
* ( | * (1) 60ML SYRINGE | ||
* (1) HIGH PRESSURE STOPCOCK | * (1) HIGH PRESSURE STOPCOCK | ||
* (1) 20ML SYRINGE | * (1) 20ML SYRINGE | ||
* 30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION) | * 30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION) | ||
== '''VALVE | == '''FOR EDWARDS VALVE''' == | ||
* INDEFLATOR | * INDEFLATOR | ||
Line 84: | Line 83: | ||
== '''Open''' == | == '''Open''' == | ||
* 14X4 | * 12X4X75 MUSTANG '''OR''' 14X4 XXL BALLOON (FROM IR) | ||
''SIZE DEPENDENT ON VALVE- CHECK WITH DANIELS BEFORE OPENING'' | |||
* PRESTO INDEFLATOR | * PRESTO INDEFLATOR | ||
Line 90: | Line 91: | ||
== '''Standby''' == | == '''Standby''' == | ||
* 9X4X135 MUSTANG | |||
* TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F) | * TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F) | ||
* 10MM, 14MM, 18MM SEPTAL OCCLUDER | * 10MM, 14MM, 18MM SEPTAL OCCLUDER | ||
Line 99: | Line 101: | ||
* (2) PERCLOSE | * (2) PERCLOSE | ||
* 3 PORT MANIFOLD | * 3 PORT MANIFOLD | ||
* ACIST- | * ACIST- FULL STRENGTH CONTRAST OK | ||
* PROBE COVER | * PROBE COVER | ||
* DUMP BAG | * DUMP BAG | ||
Line 107: | Line 109: | ||
* TAVR INSTRUMENT TRAY | * TAVR INSTRUMENT TRAY | ||
* CHLORAPREP AND PREP TRAY | * CHLORAPREP AND PREP TRAY | ||
* A LINE TUBING AND VENOUS EXTENSION FOR ANESTHESIA | |||
* DERMABOND | * DERMABOND | ||
* ( | |||
* | == '''Standby''' == | ||
* | |||
* 150ML CONTRAST (FOR CORONARIES) | |||
* BIOPATCH | |||
* FLUORO DRAPE | |||
* 8F ANGIOSEAL | |||
* 0 SILK SUTURE | |||
* EXTRA PERCLOSE | |||
= MEDICATIONS = | = MEDICATIONS = | ||
* BUPIVACAINE | * BUPIVACAINE | ||
* EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE | * EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE | ||
* ROTAGLIDE 10ML ( | * ROTAGLIDE 10ML (EDWARDS VALVE) | ||
= STANDBY EMERGENCY ECMO SUPPLIES = | = STANDBY EMERGENCY ECMO SUPPLIES = | ||
Line 135: | Line 144: | ||
* STOPCOCK | * STOPCOCK | ||
* AMPLATZ SUPER STIFF 180CM | * AMPLATZ SUPER STIFF 180CM | ||
= PROCEDURE: = | = PROCEDURE: = | ||
* Patient prepped from '''navel to knees''' in sterile fashion. | * Patient prepped from '''navel to knees''' in sterile fashion. | ||
* Access obtained with u/s | * Access obtained with u/s | ||
Typical sites: | Typical sites: | ||
*** | *** 5F LFA for anesthesia monitoring | ||
*** 8F 35cm LFV for transcutaneous pacing | *** 8F 35cm LFV for transcutaneous pacing | ||
*** | *** 14F OR 16F RFV E-sheath for valve delivery | ||
**** Dilate with 8F | **** Dilate with 8F | ||
**** Preclose | **** Preclose | ||
* SL1 inserted over .032 kit wire | * SL1 inserted over .032 kit wire | ||
* Baylis needle inserted through SL1 and atrial septum puncture performed. | * Baylis needle inserted through SL1 and atrial septum puncture performed. | ||
* Needle removed | * Needle removed, .032 wire advanced to pulmonary vein | ||
* Agilis advanced and directed to mitral valve | |||
* | * Pigtail inserted through agilis for valve crossing. | ||
* | * Safari2 wire inserted to ventricle. | ||
* Pigtail and agilis removed. | |||
* 12mm/14mm balloon advanced for septostomy and possible BAV | |||
* Balloon removed, valve delivery system advanced. | |||
* | |||
* 14mm balloon advanced for septostomy | |||
* Balloon | |||
* When valve is in place, temp pacer inserted and tested. | * When valve is in place, temp pacer inserted and tested. | ||
* Valve deployed. Septum evaluated with echo for shunting | * Valve deployed. Septum evaluated with echo for shunting. | ||
* Delivery system removed | * Pacer removed. Delivery system removed. | ||
* Preclosure closed and stitch to RFV | * Preclosure closed and stitch to RFV | ||
* Perclose LFA | * Perclose LFA | ||
* 8F vein exchanged for 9F 10cm sheath | * 8F vein exchanged for 9F 10cm sheath | ||
* Secure sheath with Statlock. Tegaderm both sides. | * Secure sheath with Statlock. Tegaderm both sides. | ||
Revision as of 15:54, 25 September 2019
Daniels
Transcather Mitral Valve Replacement
GENERAL ANESTHESIA AND TEE IMAGING
ACCESS 2 FEMORAL VEINS (TAVR AND PACER), 1 FEMORAL ARTERY (ANESTESIA)
PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN
SHEATHS:
- (1) 5F MICROPUNCTURE KIT
- (1) 5F 10CM SHEATH
- OR 6F IF CORONARY IMAGING NECESSARY
- (1) 8F 10CM SHEATH
- (1) 8F 35CM BRITE TIP SHEATH
- (1) 9F 10CM SHEATH
- (1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH
- (1) 8.5F AGILIS SMALL CURL
WIRES:
Open
- (2) .035 150CM J WIRE
- (1) SAFARI 2 WIRE
Standby
- .035 260CM J WIRE
- AMPLATZ SUPER STIFF 1CM TIP
- SUPRACORE 190CM
CATHETERS
Open
- 6F STRAIGHT PIGTAIL 110CM
Standby
- 6F LANGSTON
- 5.2F ANGLED PIGTAIL
- 5F MPA
- 5F JL4 AND JR4 (FOR CORONARIES)
PACING
- 5F JOSEPHSON PACING CATHETER
- EP QUAD CABLE
- DUAL RED/BLACK REMINGTON PACING CABLE
- (2) PACER BOXES
VALVE TABLE
- (4) STERILE BOWLS (2- 0.9% SALINE, 1-HEP SALINE, 1-15% CONTRAST MIX)
- (1) 90 INCH DRAPE (OR)
- 1L NORMAL SALINE IRRIGATION
- 500ML HEPARINIZED SALINE
- (1) 60ML SYRINGE
- (1) HIGH PRESSURE STOPCOCK
- (1) 20ML SYRINGE
- 30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION)
FOR EDWARDS VALVE
- INDEFLATOR
- CRIMPER
- E SHEATH
- DELIVERY SYSTEM
- VALVE
TRANS SEPTAL
- BAYLIS NEEDLE LARGE CURVE C1
- BAYLIS MACHINE
- BAYLIS CABLE
- GROUNDING PAD
SEPTAL DILATION
Open
- 12X4X75 MUSTANG OR 14X4 XXL BALLOON (FROM IR)
SIZE DEPENDENT ON VALVE- CHECK WITH DANIELS BEFORE OPENING
- PRESTO INDEFLATOR
Standby
- 9X4X135 MUSTANG
- TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
- 10MM, 14MM, 18MM SEPTAL OCCLUDER
ADDITIONAL SUPPLIES
Open
- (2) PERCLOSE
- 3 PORT MANIFOLD
- ACIST- FULL STRENGTH CONTRAST OK
- PROBE COVER
- DUMP BAG
- 25g 1½ INCH NEEDLE
- STAT LOCK WITH STRING SECUREMENT
- PROLENE 2-0
- TAVR INSTRUMENT TRAY
- CHLORAPREP AND PREP TRAY
- A LINE TUBING AND VENOUS EXTENSION FOR ANESTHESIA
- DERMABOND
Standby
- 150ML CONTRAST (FOR CORONARIES)
- BIOPATCH
- FLUORO DRAPE
- 8F ANGIOSEAL
- 0 SILK SUTURE
- EXTRA PERCLOSE
MEDICATIONS
- BUPIVACAINE
- EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
- ROTAGLIDE 10ML (EDWARDS VALVE)
STANDBY EMERGENCY ECMO SUPPLIES
- 16F ARTERIAL CANNULA
- 21F VENOUS CANNULA
- (2) PERCLOSE
- ECMO INSTRUMENT TRAY
- AMPLATZ SUPER STIFF
STANDBY PERICARDIOCENTESIS SUPPLIES
- EYE DRAPE
- CHIBA NEEDLE 10CM 18G
- SKATER INTRODUCER SET
- BARD LOCKING PIGTAIL 6F OR 8F
- (3) 60ML SYRINGES
- STOPCOCK
- AMPLATZ SUPER STIFF 180CM
PROCEDURE:
- Patient prepped from navel to knees in sterile fashion.
- Access obtained with u/s
Typical sites:
- 5F LFA for anesthesia monitoring
- 8F 35cm LFV for transcutaneous pacing
- 14F OR 16F RFV E-sheath for valve delivery
- Dilate with 8F
- Preclose
- SL1 inserted over .032 kit wire
- Baylis needle inserted through SL1 and atrial septum puncture performed.
- Needle removed, .032 wire advanced to pulmonary vein
- Agilis advanced and directed to mitral valve
- Pigtail inserted through agilis for valve crossing.
- Safari2 wire inserted to ventricle.
- Pigtail and agilis removed.
- 12mm/14mm balloon advanced for septostomy and possible BAV
- Balloon removed, valve delivery system advanced.
- When valve is in place, temp pacer inserted and tested.
- Valve deployed. Septum evaluated with echo for shunting.
- Pacer removed. Delivery system removed.
- Preclosure closed and stitch to RFV
- Perclose LFA
- 8F vein exchanged for 9F 10cm sheath
- Secure sheath with Statlock. Tegaderm both sides.