TMVI - Encircle Sapien M3: Difference between revisions

From Bay Area Structural Heart Wiki
(Created page with "This will be the Sapien M3 page.")
 
No edit summary
Line 1: Line 1:
This will be the Sapien M3 page.
DANIELS
 
Sapien M3
 
'''GENERAL ANESTHESIA, TEE, BIPLANE'''
 
'''ACCESS 2 FEMORAL VEINS (ESHEATH AND PACER), 1 FEMORAL ARTERY'''
 
'''TRIPLE LUMEN AND RADIAL ARTERY ACCESS BY ANESTHESIA'''
 
'''STABILIZER PLACEMENT PRIOR TO DRAPING'''
=SHEATHS:=
 
*(1) 5F MICROPUNCTURE KIT
*(1) 6F 10CM SHEATH
*(1) 8F 10CM SHEATH
*(1) 8F 35CM BRITE TIP SHEATH
*(1) 9F 10CM SHEATH
*(1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH
 
=WIRES:=
=='''Open'''==
 
*(2) .035 150CM J WIRE
*(1) .035 260CM J WIRE
*(1) SAFARI 2 WIRE
*(1) AMPLATZ SUPER STIFF 1CM TIP
 
=='''Standby'''==
 
*Baylis ProTrack wire
 
=CATHETERS=
=='''Open'''==
 
*6F STRAIGHT PIGTAIL 110CM
*6F ANGLED PIGTAIL 110CM
*5F MPA1
 
=='''Standby'''==
 
*6F MPA1 125cm
 
=PACING=
 
*5F JOSEPHSON PACING CATHETER
*EP QUAD CABLE
*DUAL RED/BLACK REMINGTON PACING CABLE
*(2) PACER BOXES
 
=VALVE TABLE=
 
*(5) STERILE BOWLS (2- 0.9% SALINE, 1-HEP SALINE, 1-15% CONTRAST MIX)
*(1) 90 INCH DRAPE
*1L NORMAL SALINE IRRIGATION
*500ML HEPARINIZED SALINE
*(2) 60ML SYRINGE
*(1) HIGH PRESSURE STOPCOCK
*(1) 20ML SYRINGE
*30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION)
*12 INCH EXTENSION
*ROTO TUBING
 
=='''VALVE- SUPPLIED BY EDWARDS'''==
 
*INDEFLATOR
*CRIMPER
*E SHEATH
*DELIVERY SYSTEM
*VALVE
 
=TRANS SEPTAL=
 
*BAYLIS NEEDLE LARGE CURVE C1
*BAYLIS MACHINE
*BAYLIS CABLE
*GROUNDING PAD
 
=SEPTAL DILATION=
=='''Open'''==
 
*14X4 ATLAS GOLD- 135 CM SHAFT PREFERRED
 
*PRESTO INDEFLATOR
 
=='''Standby'''==
 
*TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
*10MM, 14MM, 18MM SEPTAL OCCLUDER
 
=ADDITIONAL SUPPLIES=
=='''Open'''==
 
*(2) PERCLOSE
*3 PORT MANIFOLD  
*ACIST- 70/30 MIX
*PROBE COVER
*DUMP BAG
*25g 1½ INCH NEEDLE
*STAT LOCK WITH STRING SECUREMENT
*PROLENE 2-0
*TAVR INSTRUMENT TRAY
*CHLORAPREP AND PREP TRAY
*DERMABOND
*(2) FLUORO DRAPES (FOR LATERAL BASE AND ANESTHESIA POLE)
*36X36 BANDBAG (FOR LATERAL DETECTOR)
*1L HEP SALINE ON PRESSURE BAG HUNG FROM IVY POLE
*That's right, I said IVY pole.
 
=MEDICATIONS=
 
*BUPIVACAINE/LIDOCAINE MIX
*EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
*ROTAGLIDE 10ML (PRE VALVE)
 
=STANDBY EMERGENCY ECMO SUPPLIES=
 
*16F ARTERIAL CANNULA
*21F VENOUS CANNULA
*(2) PERCLOSE
*ECMO INSTRUMENT TRAY
*AMPLATZ SUPER STIFF
 
=STANDBY PERICARDIOCENTESIS SUPPLIES=
 
*EYE DRAPE
*CHIBA NEEDLE 10CM 18G
*SKATER INTRODUCER SET
*BARD LOCKING PIGTAIL 6F OR 8F
*(3) 60ML SYRINGES
*STOPCOCK
*AMPLATZ SUPER STIFF 180CM
 
=STANDBY PARAVALVULAR LEAK REPAIR SUPPLIES=
'''SEE MITRAL PARAVALVULAR LEAK REPAIR'''
 
*AMPLATZER VASCULAR PLUG 2 SIZE 8-18 AVAILABLE
 
=PROCEDURE:=
 
*Patient prepped from '''navel to knees''' in sterile fashion.  
*ISOCENTER XRAY
*Access obtained with u/s
 
Typical sites:
 
***6F LFA for Pigtail
***8F 35cm LFV for transcutaneous pacing
***20F RFV E-sheath for valve delivery
****Dilate with 8F
****Preclose
*Pigtail advanced through 6F sheath and LVgram performed
*Mitral annulus denoted on live monitor screen in A plane
*SL1 inserted over .032 kit wire
*Baylis needle inserted through SL1 and atrial septum puncture performed.
*Needle removed
*5F MPA and standard J wire advanced to pulmonary vein
*1cm Amplatz Super Stiff advanced and MPA and SL1 removed
*Edwards Guide Sheath (GS) advanced
*Dock Delivery System (DDS) advanced through GS
*Dock deployed in a timely fashion ;)
*DDS removed and MPA inserted over exchange  J for valve crossing
*J wire exchanged for Safari 2 and MPA removed
*14mm balloon advanced for septostomy
*Balloon and GS removed
*Valve delivery system advanced
*When valve is in place, temp pacer inserted and tested.
*Valve deployed. Septum evaluated with echo for shunting and PVL.
*Delivery system removed and MPA inserted for LA pressure measurement.
*All equipment removed
*Preclosure closed and stitch to RFV
*Perclose LFA
*8F vein exchanged for 9F 10cm sheath
*Secure sheath with Statlock. Tegaderm both sides.
 
<br />

Revision as of 15:02, 25 September 2019

DANIELS

Sapien M3

GENERAL ANESTHESIA, TEE, BIPLANE

ACCESS 2 FEMORAL VEINS (ESHEATH AND PACER), 1 FEMORAL ARTERY

TRIPLE LUMEN AND RADIAL ARTERY ACCESS BY ANESTHESIA

STABILIZER PLACEMENT PRIOR TO DRAPING

SHEATHS:

  • (1) 5F MICROPUNCTURE KIT
  • (1) 6F 10CM SHEATH
  • (1) 8F 10CM SHEATH
  • (1) 8F 35CM BRITE TIP SHEATH
  • (1) 9F 10CM SHEATH
  • (1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH

WIRES:

Open

  • (2) .035 150CM J WIRE
  • (1) .035 260CM J WIRE
  • (1) SAFARI 2 WIRE
  • (1) AMPLATZ SUPER STIFF 1CM TIP

Standby

  • Baylis ProTrack wire

CATHETERS

Open

  • 6F STRAIGHT PIGTAIL 110CM
  • 6F ANGLED PIGTAIL 110CM
  • 5F MPA1

Standby

  • 6F MPA1 125cm

PACING

  • 5F JOSEPHSON PACING CATHETER
  • EP QUAD CABLE
  • DUAL RED/BLACK REMINGTON PACING CABLE
  • (2) PACER BOXES

VALVE TABLE

  • (5) STERILE BOWLS (2- 0.9% SALINE, 1-HEP SALINE, 1-15% CONTRAST MIX)
  • (1) 90 INCH DRAPE
  • 1L NORMAL SALINE IRRIGATION
  • 500ML HEPARINIZED SALINE
  • (2) 60ML SYRINGE
  • (1) HIGH PRESSURE STOPCOCK
  • (1) 20ML SYRINGE
  • 30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION)
  • 12 INCH EXTENSION
  • ROTO TUBING

VALVE- SUPPLIED BY EDWARDS

  • INDEFLATOR
  • CRIMPER
  • E SHEATH
  • DELIVERY SYSTEM
  • VALVE

TRANS SEPTAL

  • BAYLIS NEEDLE LARGE CURVE C1
  • BAYLIS MACHINE
  • BAYLIS CABLE
  • GROUNDING PAD

SEPTAL DILATION

Open

  • 14X4 ATLAS GOLD- 135 CM SHAFT PREFERRED
  • PRESTO INDEFLATOR

Standby

  • TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
  • 10MM, 14MM, 18MM SEPTAL OCCLUDER

ADDITIONAL SUPPLIES

Open

  • (2) PERCLOSE
  • 3 PORT MANIFOLD  
  • ACIST- 70/30 MIX
  • PROBE COVER
  • DUMP BAG
  • 25g 1½ INCH NEEDLE
  • STAT LOCK WITH STRING SECUREMENT
  • PROLENE 2-0
  • TAVR INSTRUMENT TRAY
  • CHLORAPREP AND PREP TRAY
  • DERMABOND
  • (2) FLUORO DRAPES (FOR LATERAL BASE AND ANESTHESIA POLE)
  • 36X36 BANDBAG (FOR LATERAL DETECTOR)
  • 1L HEP SALINE ON PRESSURE BAG HUNG FROM IVY POLE
  • That's right, I said IVY pole.

MEDICATIONS

  • BUPIVACAINE/LIDOCAINE MIX
  • EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
  • ROTAGLIDE 10ML (PRE VALVE)

STANDBY EMERGENCY ECMO SUPPLIES

  • 16F ARTERIAL CANNULA
  • 21F VENOUS CANNULA
  • (2) PERCLOSE
  • ECMO INSTRUMENT TRAY
  • AMPLATZ SUPER STIFF

STANDBY PERICARDIOCENTESIS SUPPLIES

  • EYE DRAPE
  • CHIBA NEEDLE 10CM 18G
  • SKATER INTRODUCER SET
  • BARD LOCKING PIGTAIL 6F OR 8F
  • (3) 60ML SYRINGES
  • STOPCOCK
  • AMPLATZ SUPER STIFF 180CM

STANDBY PARAVALVULAR LEAK REPAIR SUPPLIES

SEE MITRAL PARAVALVULAR LEAK REPAIR

  • AMPLATZER VASCULAR PLUG 2 SIZE 8-18 AVAILABLE

PROCEDURE:

  • Patient prepped from navel to knees in sterile fashion.  
  • ISOCENTER XRAY
  • Access obtained with u/s

Typical sites:

      • 6F LFA for Pigtail
      • 8F 35cm LFV for transcutaneous pacing
      • 20F RFV E-sheath for valve delivery
        • Dilate with 8F
        • Preclose
  • Pigtail advanced through 6F sheath and LVgram performed
  • Mitral annulus denoted on live monitor screen in A plane
  • SL1 inserted over .032 kit wire
  • Baylis needle inserted through SL1 and atrial septum puncture performed.
  • Needle removed
  • 5F MPA and standard J wire advanced to pulmonary vein
  • 1cm Amplatz Super Stiff advanced and MPA and SL1 removed
  • Edwards Guide Sheath (GS) advanced
  • Dock Delivery System (DDS) advanced through GS
  • Dock deployed in a timely fashion ;)
  • DDS removed and MPA inserted over exchange  J for valve crossing
  • J wire exchanged for Safari 2 and MPA removed
  • 14mm balloon advanced for septostomy
  • Balloon and GS removed
  • Valve delivery system advanced
  • When valve is in place, temp pacer inserted and tested.
  • Valve deployed. Septum evaluated with echo for shunting and PVL.
  • Delivery system removed and MPA inserted for LA pressure measurement.
  • All equipment removed
  • Preclosure closed and stitch to RFV
  • Perclose LFA
  • 8F vein exchanged for 9F 10cm sheath
  • Secure sheath with Statlock. Tegaderm both sides.