THIS PAGE IS BASED OFF THE 1 PREVIOUS TVIR.  VERY PRELIMINARY.
Due to the open nature of the tricuspid surgical ring, PVL is highly likely post transcatheter valve placement.
Due to the open nature of the tricuspid surgical ring, PVL is highly likely post transcatheter valve placement.




Line 20: Line 24:
==Supplies==
==Supplies==


*Standard TAVR backtable setup
*Standard TAVR backtable setup with Certitude delivery system
*8F Sheath
*8F Sheath
*150 J
*150 J
Line 28: Line 32:
*6F Angled Pigtail
*6F Angled Pigtail
*0 Prolene
*0 Prolene
*Micropuncture (for woggle only)
*Micropuncture  
*Perclose x 1




Standby:  
Standby:  


*Sizing Balloon?
*5F MPA
*8.5F TourGuide
*8.5F TourGuide
*Agilis
*6F balloon wedge
*6F balloon wedge
*5F balloon tip pacer
*Pacing Supplies
 
 
'''PVL Closure:'''
 
* Plug Cart in room.  May be ASO, Cardioform, or AVP2
* Standard Glidewire for crossing
* Amplatz ES if using Trevisio/Torqvue


<br />
<br />
Line 41: Line 56:
==Procedure==
==Procedure==


*Single Venous access
*IJ access
*Double Preclose
*Maybe single preclose?
*8F Sheath inserted
*Certitude Sheath Advanced
*Pigtail and J wire advanced to RV
*Pigtail and J wire advanced to RV
*J wire exchanged for Safari
*J wire exchanged for Safari
**Shave back of Safari for pacing
**Shave back of Safari for pacing
* Sheath exchanged for E Sheath
*Valve delivery system advanced
*Valve delivery system advanced
*Pacer tested
*Pacer tested

Revision as of 22:56, 16 February 2021

THIS PAGE IS BASED OFF THE 1 PREVIOUS TVIR. VERY PRELIMINARY.


Due to the open nature of the tricuspid surgical ring, PVL is highly likely post transcatheter valve placement.


Anesthesia Imaging Access ACIST Manifold
GA Fluoro, TEE

LEFT IJ Vein

No No

Supplies

  • Standard TAVR backtable setup with Certitude delivery system
  • 8F Sheath
  • 150 J
  • 260J
  • Safari
  • Alligator Clip Pacing cable
  • 6F Angled Pigtail
  • 0 Prolene
  • Micropuncture
  • Perclose x 1


Standby:

  • Sizing Balloon?
  • 5F MPA
  • 8.5F TourGuide
  • Agilis
  • 6F balloon wedge
  • Pacing Supplies


PVL Closure:

  • Plug Cart in room. May be ASO, Cardioform, or AVP2
  • Standard Glidewire for crossing
  • Amplatz ES if using Trevisio/Torqvue


Procedure

  • IJ access
  • Maybe single preclose?
  • Certitude Sheath Advanced
  • Pigtail and J wire advanced to RV
  • J wire exchanged for Safari
    • Shave back of Safari for pacing
  • Valve delivery system advanced
  • Pacer tested
  • Valve deployed
  • Safari exchanged for J wire
  • Perclose completed and woggle placed.
  • Voila.