Carotid TAVI: Difference between revisions
From Bay Area Structural Heart Wiki
(Created page with "Procedure to be performed in Hybrid OR 14 in conjunction with the OR team. <br /> == Equipment == In addition to standard TAVR equipment the OR team will need: * Micropunct...") |
|||
Line 3: | Line 3: | ||
<br /> | <br /> | ||
== Equipment == | ==Equipment== | ||
In addition to standard TAVR equipment the OR team will need: | In addition to standard TAVR equipment the OR team will need: | ||
* Micropuncture | *Micropuncture | ||
* 6F 10cm Pinnacle Sheath | *6F 10cm Pinnacle Sheath | ||
== | ==Setup- Right Sided Carotid== | ||
* Anesthesia to get left sided A line | |||
* Table at 30 degrees | |||
* Bring C arm in perpendicular to table | |||
* OR will do prep. (Include groins and right wrist) | |||
* First assist to stand at head of bed on the left | |||
* CT surgeon on right side with scrub RN | |||
* Cath Lab will have standard 2 small tables plus high table for valve delivery. | |||
** consider using mayo stand to bridge the gap between valve table and access site |
Revision as of 15:58, 5 September 2020
Procedure to be performed in Hybrid OR 14 in conjunction with the OR team.
Equipment
In addition to standard TAVR equipment the OR team will need:
- Micropuncture
- 6F 10cm Pinnacle Sheath
Setup- Right Sided Carotid
- Anesthesia to get left sided A line
- Table at 30 degrees
- Bring C arm in perpendicular to table
- OR will do prep. (Include groins and right wrist)
- First assist to stand at head of bed on the left
- CT surgeon on right side with scrub RN
- Cath Lab will have standard 2 small tables plus high table for valve delivery.
- consider using mayo stand to bridge the gap between valve table and access site