Paravalvular leak- Mitral: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
(equipment update)
Line 3: Line 3:
All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.
All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.


=== Sheaths: ===


==== Open ====
Total Length of FlexCath: 81cm. 


* 8F pinnacle
Total Length of Agilis: 71cm
* 12F dilator
* FlexCath- structural cart.


==== Standby ====
<nowiki>****</nowiki>If Flexcath is an acceptable option, use it.  Much cheaper than agilis.*****


* 4fr x 10cm Pinnacle - (A-line)
AVPII cable length: 100cm
* Dryseal
* 90cm Shuttle sheaths


=== Wires: ===


==== Open ====
90cm Shuttle Sheath is not long enough to put into FlexCath.  Will have to remove flex cath.


* 150J
<br />
* 260J
* Glide Advantage
* Amplatz ES
* Amplatz SS 260cm
* .032 260cm J


=== Catheters: ===
===Sheaths:===


==== Open ====
====Open====


* 5F MPA 100cm
*8F pinnacle
* 5fr angled pigtail


==== Standby ====
====Standby====


* Agilis
*FlexCath
* 5fr IM diagnostic
*Agilis- small curve
* 5fr JR4 diagnostic
*4fr x 10cm Pinnacle - (A-line)
* Berenstein 125cm (Spies)
*Cook 30cm
*90cm Shuttle sheaths


=== Transseptal ===
===Wires:===


==== Open ====
====Open====


* Baylis machine
*150J
* Baylis cable
*260J
* Grounding pad
*Glide Advantage 260cm
* Large curve C1 Baylis needle
*Amplatz SS 260cm
* 8.5fr SL1 transseptal sheath
*.032 260J


=== Misc Supplies: ===
===Catheters:===


==== Open ====
====Open====


* Probe cover
*5F MPA 100cm
* Micropuncture
*5fr angled pigtail
* Perclose
* 3-port manifold (no ACIST)
* 60cc syringe


==== Standby ====
====Standby====


* Watchdog
*5fr IM diagnostic
*5fr JR4 diagnostic
*Berenstein 125cm (Spies)


=== Device embolization / retrieval: ===
===Transseptal===


==== Standby ====
====Open====


* EnSnare or Gooseneck
*Baylis machine
* 16 or 18fr x 33cm Dryseal
*Baylis cable
*Grounding pad
*Large curve C1 Baylis needle
*8.5fr SL1 transseptal sheath
 
===Misc Supplies:===
 
====Open====
 
*Probe cover
*Micropuncture
*Perclose
*3-port manifold (no ACIST)
*60cc syringe
 
====Standby====
 
*Watchdog
*stopcock
 
===Device embolization / retrieval:===
 
====Standby====
 
*EnSnare or Gooseneck
*16 or 18fr x 33cm Dryseal
*JR4 Guide


[[Category:Procedures]]
[[Category:Procedures]]

Revision as of 23:08, 9 May 2020

Various equipment needed is dependent upon size of leak.

All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.


Total Length of FlexCath: 81cm.

Total Length of Agilis: 71cm

****If Flexcath is an acceptable option, use it. Much cheaper than agilis.*****

AVPII cable length: 100cm


90cm Shuttle Sheath is not long enough to put into FlexCath. Will have to remove flex cath.


Sheaths:

Open

  • 8F pinnacle

Standby

  • FlexCath
  • Agilis- small curve
  • 4fr x 10cm Pinnacle - (A-line)
  • Cook 30cm
  • 90cm Shuttle sheaths

Wires:

Open

  • 150J
  • 260J
  • Glide Advantage 260cm
  • Amplatz SS 260cm
  • .032 260J

Catheters:

Open

  • 5F MPA 100cm
  • 5fr angled pigtail

Standby

  • 5fr IM diagnostic
  • 5fr JR4 diagnostic
  • Berenstein 125cm (Spies)

Transseptal

Open

  • Baylis machine
  • Baylis cable
  • Grounding pad
  • Large curve C1 Baylis needle
  • 8.5fr SL1 transseptal sheath

Misc Supplies:

Open

  • Probe cover
  • Micropuncture
  • Perclose
  • 3-port manifold (no ACIST)
  • 60cc syringe

Standby

  • Watchdog
  • stopcock

Device embolization / retrieval:

Standby

  • EnSnare or Gooseneck
  • 16 or 18fr x 33cm Dryseal
  • JR4 Guide