Perc. Transvenous Mitral Commissurotomy: Difference between revisions
From Bay Area Structural Heart Wiki
m (Suddemj moved page Mitral Valvuloplasty to Perc. Transvenous Mitral Commissurotomy) |
No edit summary |
||
Line 4: | Line 4: | ||
===Device:=== | ===Device:=== | ||
*Toray INOUE-Balloon Kit | *Toray INOUE-Balloon Kit | ||
Size determined using the equation (height in cm/10 +10), but verify with MD because body habitus is also a factor. | Size determined using the equation (height in cm/10 +10), but verify with MD because body habitus is also a factor. | ||
=== Sheaths: === | |||
===Sheaths:=== | |||
====Open==== | ====Open==== | ||
* | *9frx25cm Pinnacle | ||
* | *8frx10cm Pinnacle | ||
*8.5 SL1 transseptal | *8.5 SL1 transseptal | ||
=== Wires: === | ===Wires:=== | ||
====Open==== | ====Open==== | ||
Line 38: | Line 38: | ||
*(2) 3-port manifolds | *(2) 3-port manifolds | ||
*Closure | *Closure | ||
**0-Prolene | **0-Prolene | ||
**Perclose | **Perclose | ||
*Stopcock | *Stopcock | ||
Revision as of 00:40, 19 December 2019
DRAFT
Device:
- Toray INOUE-Balloon Kit
Size determined using the equation (height in cm/10 +10), but verify with MD because body habitus is also a factor.
Sheaths:
Open
- 9frx25cm Pinnacle
- 8frx10cm Pinnacle
- 8.5 SL1 transseptal
Wires:
Open
- Cordis 150J
TransSeptal Equipment:
Open
- Baylis generator from EP
- Large curve C1 Baylis needle
- Baylis cable
- Grounding pad
Misc Supplies:
Open
- Micropuncture
- US probe cover
- (2) 3-port manifolds
- Closure
- 0-Prolene
- Perclose
- Stopcock
Pericardiocentesis (Standby):
Emergency Standby:
- IABP
APPROVED: MD initials MM/YY