Hongo LLE: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
(added ecmo bare bones togo bag drop list)
Line 22: Line 22:
*2.0 pds, 3.0 monocryl, 4.0 monocryl
*2.0 pds, 3.0 monocryl, 4.0 monocryl
*0-Ethibonds for can, leads
*0-Ethibonds for can, leads
*'''ECMO bare bones togo bag - first draft 2/7/22 ZR'''
*Tray
*Straight Amplatz/7cm floppy tip X2
*Dilators (V, A)
*Cannulae (V, A)
*Bulb Syringe
*0-proline/stopcock/micropuncture for woggle
*0-ethibond for cannula to skin





Revision as of 19:04, 7 February 2022

Laser Lead Todo List v3 (last revised 11/27/2019 ZR) The following is a non-exhaustive to-do list that should be completed ahead of any Laser Lead Extraction set to be done in Lab 14, the Hybrid OR.


  • PRE-PULL LIST from lab 4 or 5 pyxis onto scrub table for transport - to ease use on Auxiliary cart
  • Call James for a blue clamshell style stock box for organization
  • EP Pack, PPM Pack, instrument tray, grey tray to transport dirty instruments post-procedure, pre-kleenz
  • Hovermat, Bear Hugger
  • Defib adaptor piece, XL split Defib pads (Silver and White, not Silver and Yellow - P-224-T1, not P-224-Z1)
  • Ground pads, EKG dots, Sp02
  • Gowns, Gloves
  • Chlorapreps
  • OR Towel packs
  • Raytex
  • Wand sleeve cover
  • 2x locking 8f
  • 1 pack of RIS tubing (2 per pack)
  • 2 stopcocks
  • 6 medium tegaderms
  • orange xtra stiff amplatzer .032
  • Green package ethilon suture
  • 2.0 pds, 3.0 monocryl, 4.0 monocryl
  • 0-Ethibonds for can, leads
  • ECMO bare bones togo bag - first draft 2/7/22 ZR
  • Tray
  • Straight Amplatz/7cm floppy tip X2
  • Dilators (V, A)
  • Cannulae (V, A)
  • Bulb Syringe
  • 0-proline/stopcock/micropuncture for woggle
  • 0-ethibond for cannula to skin


  • TODO LIST
  • Call Anesthesia Tech and ensure TEE + appropriate probe are in lab 14, plug in display cable (displayport to DVI) from TEE to 4in1 on wall
  • Check: Tyrex?
  • Load Staff + Physician Lead & Glasses onto scrub table for transport
  • Load ACT machine, cuvettes, dry erase pen, lidocaine bottle opener onto scrub table for transport
  • Pre-pull gear from EP 4 or 5 for case:
  • Put Temp Pacing Box on scrub table (JSN + cut quad cable + adaptor are already on aux cart)
  • Bring VGA cable from foot of bed in lab 4 or 5 for rep programmer, plug into 4in1 equipment boom
  • Bring surgicount + its pole/holster
  • Bring 2x lead shields: Anesthesia, and Nursing with pt info
  • Bring Main Laser Lead Cart and put in position
  • Bring Aux Laser Lead Cart and put in position
  • Bring Laser and put in position, plug into port on boom across room, calibrate
  • Set Anesthesia shield in place before moving Xray arm into position
  • Set Xray arm in position before patient is in the room (30 deg - option 6)
  • Set Neptune in position
  • Set Venue in position
  • Set screens at foot of bed (move to patient right after groin access complete)
  • Set Defib + Bovie on foot of bed, plug in below table, bovie to 30/30
  • Xray controls + lead skirts to patient left table rail (if left sided extraction)
  • Select appropriate screen setup on xray controls: anesthesia vitals + McK + xray live + xray review)
  • Find Light/Camera handle covers (either back of 14, or OR sterile core)
  • Lookup patient weight – Hovermat Y/N
  • Lookup Laser Sheath sizes
  • Blood slip (found in auxiliary cart)
  • Blood into room (make sure to bring down with 2x facesheets)
  • Make sure anesthesia has bags for KVO/KAO