(Created page with "PICC LINE PLACEMENT/EXCHANGE/TUNNELED {{Protip|Measure patient’s arm circumference before procedure to document in case of swelling later}} *Check with MD for French size* *Heparinized Saline 1000 ml ==PICC Line Placement== *Angio pack *Fluoro drape *Probe cover *Turtle shell cover *Tourniquet *Biopatch *5Fr x 135cm Dual Lumen PowerPICC SOLO catheter *Elastic Retention Netting ==PICC LINE EXCHANGE/REPOSITION== *Transcend guidewire *PICC statlock *Bi...") |
No edit summary |
||
Line 66: | Line 66: | ||
==Lynne== | ==Lynne== | ||
[[Category:IRProcedures]] |
Latest revision as of 19:09, 7 November 2024
PICC LINE PLACEMENT/EXCHANGE/TUNNELED
Protip: Measure patient’s arm circumference before procedure to document in case of swelling later
- Check with MD for French size*
- Heparinized Saline 1000 ml
PICC Line Placement
- Angio pack
- Fluoro drape
- Probe cover
- Turtle shell cover
- Tourniquet
- Biopatch
- 5Fr x 135cm Dual Lumen PowerPICC SOLO catheter
- Elastic Retention Netting
PICC LINE EXCHANGE/REPOSITION
- Transcend guidewire
- PICC statlock
- Biopatch
- Medium tegaderm
- If suspected occlusion, may need contrast*
TUNNELED PICC PLACEMENT
- Angiopack
- Fluoro drape
- Turtle shell cover
- Pickups
- Biopatch
- IV Blue caps
- Medium tegaderm
- 6Fr Powerline Polyurethane Catheter with SureCuff Ingrowth Cuff
Bronzo
- 0 Silk suture
Dare
- 4-0 Vicryl
- Exofin
Raj
- 2-0 Prolene
- 4-0 Vicryl
Brittany
- 22G Angiocath (Blue)