Tooley Device Preferences: Difference between revisions

From Bay Area Structural Heart Wiki
Rosenbzj (talk | contribs)
Created page with "8.5 single glove Micropuncture Ultrasound for 1st attempt at access before making a pocket, 2nd attempt use 30 caudal after confirming location in AP Venogram as needed Wet towel for hands, pickup with teeth 0 ethibond for leads/generator 2-0 PDS 3-0 Monocryl 4-0 Monocryl Dermabond Curad + Tegaderm Ask for pressure dressing Arm sling - 1 day"
 
No edit summary
Line 20: Line 20:
Ask for pressure dressing
Ask for pressure dressing
Arm sling - 1 day
Arm sling - 1 day
[[Category:Devices]]

Revision as of 21:30, 7 January 2025

8.5 single glove

Micropuncture

Ultrasound for 1st attempt at access before making a pocket, 2nd attempt use 30 caudal after confirming location in AP

Venogram as needed

Wet towel for hands, pickup with teeth

0 ethibond for leads/generator 2-0 PDS 3-0 Monocryl 4-0 Monocryl

Dermabond

Curad + Tegaderm

Ask for pressure dressing Arm sling - 1 day