Christian Spies M.D.: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 3: | Line 3: | ||
|Access=U/s for all access, Keep probe on field like PH does. Wet blue towel on pts. Lap. | |Access=U/s for all access, Keep probe on field like PH does. Wet blue towel on pts. Lap. | ||
|Radial Setup=5/6 Slender and 5 F JL3.5 / JR4 | |Radial Setup=5/6 Slender and 5 F JL3.5 / JR4 | ||
|Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, No nitro on table. Nitro on standby. Ok to mix verap and heparin | |Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, No nitro on table.,Nitro on standby. Ok to mix verap and heparin | ||
|Groin Setup=6fr sheath, JL4 / JR4 | |Groin Setup=6fr sheath, JL4 / JR4 | ||
|Closure Device=Perclose | |Closure Device=Perclose |
Revision as of 16:08, 20 May 2024
Glove size | 8 |
---|---|
Access |
|
Radial Setup |
|
Radial Cocktail |
|
Groin Setup |
|
Closure Device |
|
Right Heart Setup |
|
Intervention Setup | |
Phone Number | 1-415-707-9939 |
Pager Number |
No Acist for Right heart procedures, manifold only!
Prefers Minamo wire for intervention
Post Transplant LHC with IVUS
Groin
- 6fr. Sheath
- 6fr. Guide
- Runthrough
- IVUS catheter
Radial
- Same with radial sheath
- 6fr. Brachial
- 6fr. PA catheter