ECMO Decan: Difference between revisions
From Bay Area Structural Heart Wiki
(Created page with "=== OPEN=== *Cath Pack *Ecmo Instrument Tray *Perclose *MicroPucture *.035x150 J wire *0-Prolene *3 way stopcock") |
No edit summary |
||
Line 2: | Line 2: | ||
*Cath Pack | *Cath Pack | ||
*Ecmo Instrument Tray | *Ecmo Instrument Tray | ||
*Perclose | *Perclose ( extras on standby ) | ||
*MicroPucture | *MicroPucture | ||
*.035x150 J wire | *.035x150 J wire | ||
*0-Prolene | *0-Prolene | ||
*3 way stopcock | *3 way stopcock | ||
=== Procedure === | |||
# Remove distal suture, leave proximal sutures for MD to cut. | |||
# Prep and Drape open drape window to expose canula. | |||
# Heavy scissors and tubing clamps up at groin. | |||
# Use micro puncture to access arterial canula. | |||
# Use .035 wire into micro puncture sheath. | |||
# Remove canula. | |||
# Perclose. | |||
# Purse string around vein 0 prolene and 3 way stop cock for woggle. |
Revision as of 22:11, 24 November 2021
OPEN
- Cath Pack
- Ecmo Instrument Tray
- Perclose ( extras on standby )
- MicroPucture
- .035x150 J wire
- 0-Prolene
- 3 way stopcock
Procedure
- Remove distal suture, leave proximal sutures for MD to cut.
- Prep and Drape open drape window to expose canula.
- Heavy scissors and tubing clamps up at groin.
- Use micro puncture to access arterial canula.
- Use .035 wire into micro puncture sheath.
- Remove canula.
- Perclose.
- Purse string around vein 0 prolene and 3 way stop cock for woggle.