Mitral Clip: Difference between revisions
No edit summary |
No edit summary |
||
Line 85: | Line 85: | ||
*BRK1 transseptal needle (Rarely used) | *BRK1 transseptal needle (Rarely used) | ||
=== Wires: === | ===Wires:=== | ||
==== Open ==== | ====Open==== | ||
*(1) Cordis .035 X 260 “J” wire | |||
*(1) Cordis .035 X 150 “J” wire | |||
*(1) Amplatz SuperStiff 1cm Tip | |||
====Standby==== | |||
*(1) .032 X 260 “J” wire | |||
*(1) .014 X 190 BMW wire | |||
===Catheters:=== | |||
==== | ====Open==== | ||
* (1) | *(1) 5F MPA2<br /> | ||
=== | === Misc supplies: === | ||
==== Open ==== | ==== Open ==== | ||
* (1) | * (2) 108cm High pressure IV Lines | ||
* (5) High Pressure Stopcock | |||
* (1) 8F Sheath for dilator - (also used as a backup sheath) | |||
* (1) Perclose | |||
* (1) 2-0 Prolene suture | |||
* (1) Probe cover | |||
* (2) 60cc syringe | |||
* (1) 12” extension (Keep stickers to label flush tubing) | |||
* (3) Sterile towel packs for back table | |||
* (1) 3 port manifold to measure LA pressure only | |||
* (1) Fluoro cover to anesthesia Ivy pole or moving xray shield - (Room 14) | |||
* (1) 20F Dilator (Spies only) | |||
==== Standby ==== | |||
* Perclose | |||
* ”0” PDS or silk for groin suture | |||
* Pericardiocentesis supplies | |||
* | |||
* supplies | |||
==Procedure== | ==Procedure== | ||
Line 113: | Line 138: | ||
Start line with a space | Start line with a space | ||
More spaces inset more | More spaces inset more | ||
[[Category:Procedures]] | |||
APPROVED: MD initials MM/YY | APPROVED: MD initials MM/YY |
Revision as of 16:34, 4 October 2019
DRAFT
Mitral Clip | |||||
---|---|---|---|---|---|
Anesthesia | Imaging | Access | Pre-Procedure | ||
General | Fluoro, TEE, and ICE |
|
Mitral Clip
Open:
(1) Liter pressure bags
(2) 108cm High pressure Ivy Lines
(5) High Pressure Stopcock
(1) 8F Dilator
(1) 20F Dilator for CS
(1) 5F MPA2
(1) Amplatz SuperStiff 1cm Tip
(1) .035 X 260 “J” wire
(1) .035 x 150 “J” wire
(1) 8.5 F SL1
(1) Baylis large curve transeptal needle and cable
(1) Perclose
(1) 2-0 Prolene suture
(1) Probe cover
(2) 60cc syringe
(1) 12” extension (Keep stickers to label flush tubing)
(3) Sterile towel packs for back table
(1) 3 port manifold to measure LA pressure only
(1) Fluoro cover to anesthesia Ivy pole or moving xray shield
Procedure:
Prior to prepping patient, place MitralClip Plate (plexiglass board – hinge side up) under patient’s leg off center to the right. Place MitralClip Lift (step stool) over patients right leg, angled down towards the head. Measure 80cm from mid-sternum to leading edge of stool. Make sure there is direct contact between stool and plate.
Prep patient and drape per usual. Make sure to drape anesthesia pole and or xray shield.
Big Equipment:
Open
- (1) Cath pack
- (1) Lift / Footstool / Support base
- (1) Clear Plexiglass base support
- (1) Sterile System Stabilizer
- (1) Baylis generator
Baylis/transseptal:
Open
- (1) SL1 TransSeptal sheath
- (1) Large curve Baylis needle
- (1) Baylis cable
- (1) Grounding pad
Standby
- BRK1 transseptal needle (Rarely used)
Wires:
Open
- (1) Cordis .035 X 260 “J” wire
- (1) Cordis .035 X 150 “J” wire
- (1) Amplatz SuperStiff 1cm Tip
Standby
- (1) .032 X 260 “J” wire
- (1) .014 X 190 BMW wire
Catheters:
Open
- (1) 5F MPA2
Misc supplies:
Open
- (2) 108cm High pressure IV Lines
- (5) High Pressure Stopcock
- (1) 8F Sheath for dilator - (also used as a backup sheath)
- (1) Perclose
- (1) 2-0 Prolene suture
- (1) Probe cover
- (2) 60cc syringe
- (1) 12” extension (Keep stickers to label flush tubing)
- (3) Sterile towel packs for back table
- (1) 3 port manifold to measure LA pressure only
- (1) Fluoro cover to anesthesia Ivy pole or moving xray shield - (Room 14)
- (1) 20F Dilator (Spies only)
Standby
- Perclose
- ”0” PDS or silk for groin suture
- Pericardiocentesis supplies
- supplies
Procedure
- Bullet list of typical procedure steps
- More steps
Inset alternative steps or notes Start line with a space More spaces inset more
APPROVED: MD initials MM/YY