Daniels
{{Warn|This page needs revision!}}<BR>
{{Protip|Need Alcohol in lab for this procedure!}}


Transcather Mitral Valve Replacement
'''TransCatheter Mitral Valve Repair/Replacement'''


'''GENERAL ANESTHESIA AND TEE IMAGING'''
Per Rosalie:


'''ACCESS 2 FEMORAL VEINS (TAVR AND PACER), 1 FEMORAL ARTERY (ANESTESIA)'''
TAVR/TMVI


'''PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN'''
#Edwards Sapien 3 Ultra (20, 23 & 26mm) and Sapien 3 (29mm) – scan the valve barcode (box) in McKesson for documentation and charges.  Bundle includes valve, delivery system, crimper, e sheath intro set, balloon cath & locking syringe.  With the new inventory system (POU) space is limited in entering item full description.   If pre dilatation Edwards balloon is necessary free text the balloon used in procedure notes (McKesson).
#Medtronic Core Valve – all items are charge separately.  Scan all barcodes (delivery system, loading system and valve).


= SHEATHS: =
MITRAL CLIP (Mitral/Tricuspid):


* (1) 5F MICROPUNCTURE KIT
#Use the barcode on Mckesson screen in Lab 1 – Mitraclip (Abbott) bundle consists of (1) Steerable Guide Catheter, (2) NTR Clip Delivery System & (1) XTR Clip Delivery System.
* (1) 5F 10CM SHEATH
{| class="wikitable"
*** '''OR''' 6F IF CORONARY IMAGING NECESSARY
|+
* (1) 8F 10CM SHEATH
! colspan="4" |TMVR
* (1) 8F 35CM BRITE TIP SHEATH
|-
* (1) 9F 10CM SHEATH
!Anesthesia
* (1) 8.5F 63CM SL1 TRANSSEPTAL SHEATH
!Imaging
* (1) 8.5F AGILIS SMALL CURL
!Access
!Pre-Procedure
|-
|
* General Anesthesia


= WIRES: =
* A-Line Always!
|
* Single Plane Fluoro


== '''Open''' ==
* TEE


* (2) .035 150CM J WIRE
* No Acist
* (1) SAFARI 2 WIRE
* Unipolar pacing
|


== '''Standby''' ==
* RVF pre-closed x 1
|
* Type and Cross


* .035 260CM J WIRE
* Aspirin Given
* AMPLATZ SUPER STIFF 1CM TIP
|}
* SUPRACORE 190CM
==Open:==
===SHEATHS:===
*Micropuncture
*8fr Pinnacle for Perclose
*Perclose (If Spies is primary, NO perclose if Daniles is primary.)
*8. 5F Agilis
*16F E sheath, '''always''', regardless of valve size.


= CATHETERS =
=== WIRES: ===
*150 J wire
*Safari 2


== '''Open''' ==
===* NEW - Baylis Transseptal===


* 6F STRAIGHT PIGTAIL 110CM
* VersaCross system
* Grounding pad


== '''Standby''' ==
===Bellow items on standby!===*SL1 sheath
* Large curve Baylis needle
*Baylis cable
*0.32 x 260 J-wire
=== MISC: ===
*Naked 3 Port Manifold
*Alligator pacing cable


* 6F LANGSTON
=== CATHETERS: ===
* 5.2F ANGLED PIGTAIL
* 5F MPA
* 5F JL4 AND JR4 (FOR CORONARIES)


= PACING =
*6fr. Straight Pig


* 5F JOSEPHSON PACING CATHETER
=== SEPTAL DILATION: ===
* EP QUAD CABLE
*12X4X75 MUSTANG '''for 23mm and 26mm Sapien OR''' 14mm Armada '''for 29mm Sapien'''
* DUAL RED/BLACK REMINGTON PACING CABLE
*PRESTO INDEFLATOR
* (2) PACER BOXES
===BIPOLAR PACING ON STANDBY:===
*8x35 Brite tip
*5F Josephson Pacing Cable
*EP Quad Cable
*Remington Pacing Cable
*(2) Pacer Boxes
===FOR EDWARDS VALVE:===
*Indeflator (Second Indeflator on standby)
*Crimper
*E-sheath (Second E-Sheath on standby)
*Delivery system (Second delivery on standby)
*Valve
==Standby==
*9X4X75 MUSTANG
*14, 16 XXL Balloons
*TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
*10MM, 14MM, 18MM SEPTAL OCCLUDER


= VALVE TABLE =
==MEDICATIONS==


* (4) STERILE BOWLS (2- 0.9% SALINE, 1-HEP SALINE, 1-15% CONTRAST MIX)
*BUPIVACAINE
* (1) 90 INCH DRAPE (OR)
*EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
* 1L NORMAL SALINE IRRIGATION
*ROTAGLIDE 10ML (EDWARDS VALVE)
* 500ML HEPARINIZED SALINE
* (1) 60ML SYRINGE
* (1) HIGH PRESSURE STOPCOCK
* (1) 20ML SYRINGE
* 30ML CONTRAST (MIX WITH 170ML HEP SALINE FOR 15% CONCENTRATION)


== '''FOR EDWARDS VALVE''' ==
==PROCEDURE:==


* INDEFLATOR
*Patient prepped from '''navel to knees''' in sterile fashion.  
* CRIMPER
*Access obtained with u/s
* E SHEATH
*Dilate with 8F dilator
* DELIVERY SYSTEM
*Preclose, Versacross pigtail wire advanced through perclose
* VALVE
*Versacross sheath inserted
*Transeptal puncture, then pigtail wire advanced
*Versacross sheath removed
*Agilis advanced and directed to mitral valve.
*Pigtail and Safari2 inserted through Agilis for valve crossing.
*Safari2 wire inserted to ventricle. Simultaneous LA/LV pressure recorded.
*Pigtail and Agilis removed.
*12mm/14mm balloon advanced for septostomy and possible BAV
*Balloon removed, valve delivery system advanced.
*When valve is in place, black alligator cable attached and pacing tested.
*Valve deployed. Septum evaluated with echo for shunting.
*Delivery removed and SL1 re-advanced.
*Pigtail advanced to LV, wire removed and simultaneous LA/LV pressures recorded (maybe).
*Pigtail and SL1 removed.
*Pacer removed.
*Preclosure completed and stitch to RFV
*Dermabond access site, no dressings needed.


= TRANS SEPTAL =


* BAYLIS NEEDLE LARGE CURVE C1
== STANDBY EMERGENCY ECMO SUPPLIES ==
* BAYLIS MACHINE
* BAYLIS CABLE
* GROUNDING PAD
 
= SEPTAL DILATION =
 
== '''Open''' ==
 
* 12X4X75 MUSTANG '''OR''' 14X4 XXL BALLOON (FROM IR)
 
''SIZE DEPENDENT ON VALVE- CHECK WITH DANIELS BEFORE OPENING''
 
* PRESTO INDEFLATOR
 
== '''Standby''' ==
 
* 9X4X135 MUSTANG
* TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
* 10MM, 14MM, 18MM SEPTAL OCCLUDER
 
= ADDITIONAL SUPPLIES =
 
== '''Open''' ==
 
* (2) PERCLOSE
* 3 PORT MANIFOLD  
* ACIST- FULL STRENGTH CONTRAST OK
* PROBE COVER
* DUMP BAG
* 25g 1½ INCH NEEDLE
* STAT LOCK WITH STRING SECUREMENT
* PROLENE 2-0
* TAVR INSTRUMENT TRAY
* CHLORAPREP AND PREP TRAY
* A LINE TUBING AND VENOUS EXTENSION FOR ANESTHESIA
* DERMABOND
 
== '''Standby''' ==
 
* 150ML CONTRAST (FOR CORONARIES)
* BIOPATCH
* FLUORO DRAPE
* 8F ANGIOSEAL
* 0 SILK SUTURE
* EXTRA PERCLOSE
 
= MEDICATIONS =
 
* BUPIVACAINE
* EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
* ROTAGLIDE 10ML (EDWARDS VALVE)
 
= STANDBY EMERGENCY ECMO SUPPLIES =


* 16F ARTERIAL CANNULA
* 16F ARTERIAL CANNULA
* 21F VENOUS CANNULA
* (2) PERCLOSE
* ECMO INSTRUMENT TRAY
* AMPLATZ SUPER STIFF
= STANDBY PERICARDIOCENTESIS SUPPLIES =
* EYE DRAPE
* CHIBA NEEDLE 10CM 18G
* SKATER INTRODUCER SET
* BARD LOCKING PIGTAIL 6F OR 8F
* (3) 60ML SYRINGES
* STOPCOCK
* AMPLATZ SUPER STIFF 180CM
= PROCEDURE: =


* Patient prepped from '''navel to knees''' in sterile fashion.  
*21F VENOUS CANNULA
* Access obtained with u/s
*(2) PERCLOSE
*ECMO INSTRUMENT TRAY
*AMPLATZ SUPER STIFF


Typical sites:
==STANDBY PERICARDIOCENTESIS SUPPLIES==


*** 5F LFA for anesthesia monitoring
*EYE DRAPE
*** 8F 35cm LFV for transcutaneous pacing
*CHIBA NEEDLE 10CM 18G
*** 14F OR 16F RFV E-sheath for valve delivery
*SKATER INTRODUCER SET
**** Dilate with 8F  
*BARD LOCKING PIGTAIL 6F OR 8F
**** Preclose
*(3) 60ML SYRINGES
* SL1 inserted over .032 kit wire
*STOPCOCK
* Baylis needle inserted through SL1 and atrial septum puncture performed.
*AMPLATZ SUPER STIFF 180CM
* Needle removed, .032 wire advanced to pulmonary vein
* Agilis advanced and directed to mitral valve
* Pigtail inserted through agilis for valve crossing.
* Safari2 wire inserted to ventricle.
* Pigtail and agilis removed.
* 12mm/14mm balloon advanced for septostomy and possible BAV
* Balloon removed, valve delivery system advanced.
* When valve is in place, temp pacer inserted and tested.
* Valve deployed. Septum evaluated with echo for shunting.
* Pacer removed. Delivery system removed.
* Preclosure closed and stitch to RFV
* Perclose LFA
* 8F vein exchanged for 9F 10cm sheath
* Secure sheath with Statlock. Tegaderm both sides.


</br>
<br>
[[Category:Procedures]]
[[Category:Procedures]]
<HR>
[[Category:NeedsWork]]
<HR />
APPROVED: MD initials MM/YY
APPROVED: MD initials MM/YY

Latest revision as of 22:13, 9 May 2024

Note Warning: This page needs revision!
Note Protip: Need Alcohol in lab for this procedure!

TransCatheter Mitral Valve Repair/Replacement

Per Rosalie:

TAVR/TMVI

  1. Edwards Sapien 3 Ultra (20, 23 & 26mm) and Sapien 3 (29mm) – scan the valve barcode (box) in McKesson for documentation and charges.  Bundle includes valve, delivery system, crimper, e sheath intro set, balloon cath & locking syringe.  With the new inventory system (POU) space is limited in entering item full description.   If pre dilatation Edwards balloon is necessary free text the balloon used in procedure notes (McKesson).
  2. Medtronic Core Valve – all items are charge separately.  Scan all barcodes (delivery system, loading system and valve).

MITRAL CLIP (Mitral/Tricuspid):

  1. Use the barcode on Mckesson screen in Lab 1 – Mitraclip (Abbott) bundle consists of (1) Steerable Guide Catheter, (2) NTR Clip Delivery System & (1) XTR Clip Delivery System.
TMVR
Anesthesia Imaging Access Pre-Procedure
  • General Anesthesia
  • A-Line Always!
  • Single Plane Fluoro
  • TEE
  • No Acist
  • Unipolar pacing
  • RVF pre-closed x 1
  • Type and Cross
  • Aspirin Given

Open:

SHEATHS:

  • Micropuncture
  • 8fr Pinnacle for Perclose
  • Perclose (If Spies is primary, NO perclose if Daniles is primary.)
  • 8. 5F Agilis
  • 16F E sheath, always, regardless of valve size.

WIRES:

  • 150 J wire
  • Safari 2

* NEW - Baylis Transseptal

  • VersaCross system
  • Grounding pad

===Bellow items on standby!===*SL1 sheath

  • Large curve Baylis needle
  • Baylis cable
  • 0.32 x 260 J-wire

MISC:

  • Naked 3 Port Manifold
  • Alligator pacing cable

CATHETERS:

  • 6fr. Straight Pig

SEPTAL DILATION:

  • 12X4X75 MUSTANG for 23mm and 26mm Sapien OR 14mm Armada for 29mm Sapien
  • PRESTO INDEFLATOR

BIPOLAR PACING ON STANDBY:

  • 8x35 Brite tip
  • 5F Josephson Pacing Cable
  • EP Quad Cable
  • Remington Pacing Cable
  • (2) Pacer Boxes

FOR EDWARDS VALVE:

  • Indeflator (Second Indeflator on standby)
  • Crimper
  • E-sheath (Second E-Sheath on standby)
  • Delivery system (Second delivery on standby)
  • Valve

Standby

  • 9X4X75 MUSTANG
  • 14, 16 XXL Balloons
  • TORQUEVUE 45DEGREE DELIVERY SYSTEM (9F OR 10F)
  • 10MM, 14MM, 18MM SEPTAL OCCLUDER

MEDICATIONS

  • BUPIVACAINE
  • EPINEPHRINE 10MCG/ML IN RED SYRINGE ON BACK TABLE
  • ROTAGLIDE 10ML (EDWARDS VALVE)

PROCEDURE:

  • Patient prepped from navel to knees in sterile fashion.  
  • Access obtained with u/s
  • Dilate with 8F dilator
  • Preclose, Versacross pigtail wire advanced through perclose
  • Versacross sheath inserted
  • Transeptal puncture, then pigtail wire advanced
  • Versacross sheath removed
  • Agilis advanced and directed to mitral valve.
  • Pigtail and Safari2 inserted through Agilis for valve crossing.
  • Safari2 wire inserted to ventricle. Simultaneous LA/LV pressure recorded.
  • Pigtail and Agilis removed.
  • 12mm/14mm balloon advanced for septostomy and possible BAV
  • Balloon removed, valve delivery system advanced.
  • When valve is in place, black alligator cable attached and pacing tested.
  • Valve deployed. Septum evaluated with echo for shunting.
  • Delivery removed and SL1 re-advanced.
  • Pigtail advanced to LV, wire removed and simultaneous LA/LV pressures recorded (maybe).
  • Pigtail and SL1 removed.
  • Pacer removed.
  • Preclosure completed and stitch to RFV
  • Dermabond access site, no dressings needed.


STANDBY EMERGENCY ECMO SUPPLIES

  • 16F ARTERIAL CANNULA
  • 21F VENOUS CANNULA
  • (2) PERCLOSE
  • ECMO INSTRUMENT TRAY
  • AMPLATZ SUPER STIFF

STANDBY PERICARDIOCENTESIS SUPPLIES

  • EYE DRAPE
  • CHIBA NEEDLE 10CM 18G
  • SKATER INTRODUCER SET
  • BARD LOCKING PIGTAIL 6F OR 8F
  • (3) 60ML SYRINGES
  • STOPCOCK
  • AMPLATZ SUPER STIFF 180CM



APPROVED: MD initials MM/YY