(Created page with "TRANSJUGULAR LIVER BX W/WO PRESSURES *100% Contrast (hand injection) unless the Physician states otherwise. *Heparinized Saline 1000 ml ==Supplies== ===Open=== *Angio pack *Micropuncture kit *Amplatz 180cm *Glide wire 180cm *Transducer *Torque device *9Fr sheath *TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle) *12cc syringe, for extra contrast *Telfa (to place specimen on) *Sureseal ===Standby=== *C2 catheter ===With pressures===...") |
No edit summary |
||
(6 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
*Heparinized Saline 1000 ml | *Heparinized Saline 1000 ml | ||
*T table setup, work from head side. | |||
*Tube left side, tilt table and tube to visualize liver. | |||
*Will measure pressures. | |||
*PPM indicates pressure measurements | |||
==Supplies== | ==Supplies== | ||
===Open=== | ===Open=== | ||
*Angio pack | *Angio pack | ||
*Fluoro drape | |||
*Probe cover | |||
*Micropuncture kit | *Micropuncture kit | ||
*Amplatz 180cm | *Amplatz SS 180cm | ||
*Glide wire 180cm | *Glide wire angled regular 180cm | ||
*Transducer | *Pressure Transducer | ||
*Torque device | *Torque device | ||
* | *9x38 Cook sheath (near tlab set) | ||
*TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle) | *TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle) | ||
*12cc syringe, for extra contrast | *12cc syringe, for extra contrast | ||
*Telfa (to place specimen on) | *Telfa (to place specimen on) | ||
*Sureseal | *Sureseal | ||
===Standby=== | ===Standby=== | ||
Line 28: | Line 34: | ||
==Bronzo | ==Bronzo== | ||
*No torque device | *No torque device | ||
==Dare== | ==Dare== | ||
Line 50: | Line 55: | ||
==Lynne== | ==Lynne== | ||
*Flowswitch | *Flowswitch | ||
[[Category:IRProcedures]] |
Latest revision as of 20:59, 20 November 2024
TRANSJUGULAR LIVER BX W/WO PRESSURES
- 100% Contrast (hand injection) unless the Physician states otherwise.
- Heparinized Saline 1000 ml
- T table setup, work from head side.
- Tube left side, tilt table and tube to visualize liver.
- Will measure pressures.
- PPM indicates pressure measurements
Supplies
Open
- Angio pack
- Fluoro drape
- Probe cover
- Micropuncture kit
- Amplatz SS 180cm
- Glide wire angled regular 180cm
- Pressure Transducer
- Torque device
- 9x38 Cook sheath (near tlab set)
- TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle)
- 12cc syringe, for extra contrast
- Telfa (to place specimen on)
- Sureseal
Standby
- C2 catheter
With pressures
- 8mm Occlusion balloon
- One way stopcock
Bronzo
- No torque device
Dare
Raj
- Flowswitch
Brittany
Will use cope wire in the kit
Evan
Micropuncture kit (Cook)
Samir
- 10Fr dilator
Lynne
- Flowswitch