Port Placement / Removal: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 9: | Line 9: | ||
*Fluoro drape | *Fluoro drape | ||
*Turtle shell cover | *Turtle shell cover | ||
*Light handle cover | |||
*<nowiki>#</nowiki>15 Blade | *<nowiki>#</nowiki>15 Blade | ||
*Raytex | *Raytex | ||
Line 22: | Line 23: | ||
*Do not connect catheter on the port | *Do not connect catheter on the port | ||
*Stratafix 3.0 & Stratafix 4.0 (or ask) | *Stratafix 3.0 & Stratafix 4.0 (or ask) | ||
*No dressing, leave it open | *No dressing, leave it open. | ||
*Syringe->0->tubing->Tunneler | |||
*Cap on tubing, port will be at zero | |||
#Micropuncture and wire | |||
#Pocket | |||
#Tunnel north | |||
#.035 wire -> peel away | |||
#Catheter goes in | |||
#Pullback under fluoro and cut | |||
#Hookup and close | |||
==Dare== | ==Dare== |
Latest revision as of 17:32, 18 November 2024
PORT PLACEMENT/REMOVAL
- Heparinized Saline 1000 ml
Supplies
- Angio pack
- Micro puncture Kit
- Probe cover
- Fluoro drape
- Turtle shell cover
- Light handle cover
- #15 Blade
- Raytex
- Sutures (see MD preference below)
- Pickups
- Exofin
- Ioban
- 8Fr Powerport (check with MD)
Bronzo
- Do not connect catheter on the port
- Stratafix 3.0 & Stratafix 4.0 (or ask)
- No dressing, leave it open.
- Syringe->0->tubing->Tunneler
- Cap on tubing, port will be at zero
- Micropuncture and wire
- Tunnel north
- .035 wire -> peel away
- Catheter goes in
- Pullback under fluoro and cut
- Hookup and close
Dare
- 3-0 Vicryl
- Connect catheter to the port
- No dressing, leave it open
Raj
- Flow switch
- 3-0 Vicryl
- Connect catheter to the port
- Steri strips for incision site (cut small) for post dressing
Brittany
- 3.0 Vicryl
- 4-0 PS-2 Coated Vicryl
- Connect catheter to the port
- No dressing, leave it open
Evan
- Micropuncture kit (Cook)
Samir
Lynne
- 3-0 Vicryl
- ¼” Steri strips for post dressing
- Cope wire
- Connect catheter to port
- Measure wire
If leaving accessed
- Two IV blue caps
- Biopatch
- Slit gauze
- 4x4 gauze
PORT REMOVAL
- Angio pack
- Raytex
- 3-0 Vicryl
- 4-0 Vicryl
- #15 Blade
- Pickups
- Exofin
- Ioban
Bronzo
No dressing likes to leave it open.
Dare
- Use telfa and medium tegaderm for dressing.
Raj
Brittany
- No dressing, leave it open