(Created page with "Balloon-occluded Retrograde Transvenous Obliteration * 100% Contrast (hand injection) unless the Physician states otherwise. *Heparinized Saline 1000 ml ==Supplies== *Angio pack *Micro puncture kit *Probe cover *Turtle shell cover *Fluoro drape *Amplatz guide wire 180cm *Amplatz guide wire 1cm Tip *Glide wire *Torque device *C2 catheter *Angled Glide catheter *MPB *(2) 45cm Destination sheath (ask MD for French size) *CO2 *Sotradecol or Sodium Tetra...")
 
No edit summary
 
Line 34: Line 34:
*10cc syringe for CO2   
*10cc syringe for CO2   
*Attach 3-way stopcock and mix both 20cc syringes.
*Attach 3-way stopcock and mix both 20cc syringes.
[[Category:IRProcedures]]

Latest revision as of 15:07, 24 October 2024

Balloon-occluded Retrograde Transvenous Obliteration

  • 100% Contrast (hand injection) unless the Physician states otherwise.
  • Heparinized Saline 1000 ml

Supplies

  • Angio pack
  • Micro puncture kit
  • Probe cover
  • Turtle shell cover
  • Fluoro drape
  • Amplatz guide wire 180cm
  • Amplatz guide wire 1cm Tip
  • Glide wire
  • Torque device
  • C2 catheter
  • Angled Glide catheter
  • MPB
  • (2) 45cm Destination sheath (ask MD for French size)
  • CO2
  • Sotradecol or Sodium Tetradecyl Sulfate (STS) & Lipiodol – Pharmacy*


Standby

  • 5.5 Fogarty balloon
  • Occlusion balloon


Drugs mixture (Dare)

  • 3-way stopcock
  • (2) 20ml syringes (for STS & Lipiodol)
  • 10cc syringe for CO2