An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated. | An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated. | ||
== Equipment: Daniels == | |||
* Indiflator | |||
* | * Naked 3 port manifold for LA pressure | ||
* | * Sheath , one French size larger then minimum balloon size | ||
* | * Balloon, size determined via ECHO | ||
* | |||
* | ===* NEW - Baylis Transseptal=== | ||
* | * VersaCross system | ||
*Grounding pad | |||
* | ===STANDBY!=== | ||
* | *SL1 TransSeptal sheath | ||
*Large curve Baylis needle | |||
*Baylis cable | *Baylis cable | ||
==== | *.032 X 260 “J” wire | ||
* | *Amplatz SuperStiff 1cm Tip 260cm | ||
*5F MPA2 | |||
== Equipment: Spies == | |||
* Indeflator | |||
* Naked 3 port manifold for LA pressure | |||
===* NEW - Baylis Transseptal=== | |||
* VersaCross system | |||
*Grounding pad | |||
===STANDBY!=== | |||
*SL1 TransSeptal sheath | |||
*Large curve Baylis needle | |||
*Baylis cable | |||
*.032 X 260 “J” wire | |||
*SuperStiff 1cm Tip 260cm | |||
*5F MPA2 | |||
===Procedure requires Baylis=== | ===Procedure requires Baylis=== | ||
*Baylis generator | *Baylis generator | ||
Line 27: | Line 44: | ||
===Balloon size determined by MD.=== | ===Balloon size determined by MD.=== | ||
*Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above. | *Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above. | ||
*Have a 22 | *Have a 22 True balloon on standby for Spies and Daniels | ||
<br /> | <br /> | ||
<hr /> | <hr /> | ||
Approved: MD initials MM/YY | Approved: MD initials MM/YY | ||
[[Category:Procedures]] | [[Category:Procedures]] |
Latest revision as of 19:40, 11 October 2024
An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated.
Equipment: Daniels
- Indiflator
- Naked 3 port manifold for LA pressure
- Sheath , one French size larger then minimum balloon size
- Balloon, size determined via ECHO
* NEW - Baylis Transseptal
- VersaCross system
- Grounding pad
STANDBY!
- SL1 TransSeptal sheath
- Large curve Baylis needle
- Baylis cable
- .032 X 260 “J” wire
- Amplatz SuperStiff 1cm Tip 260cm
- 5F MPA2
Equipment: Spies
- Indeflator
- Naked 3 port manifold for LA pressure
* NEW - Baylis Transseptal
- VersaCross system
- Grounding pad
STANDBY!
- SL1 TransSeptal sheath
- Large curve Baylis needle
- Baylis cable
- .032 X 260 “J” wire
- SuperStiff 1cm Tip 260cm
- 5F MPA2
Procedure requires Baylis
- Baylis generator
- Grounding Pad
Balloon size determined by MD.
- Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above.
- Have a 22 True balloon on standby for Spies and Daniels
Approved: MD initials MM/YY