| Line 24: | Line 24: | ||
*Watchdog | *Watchdog | ||
*stopcock | *stopcock | ||
*Mustang for septostomy | |||
*priority pack | |||
*180* torqvue (French size not important here, only using for the cable.) | |||
===Sheaths:=== | ===Sheaths:=== | ||
| Line 31: | Line 34: | ||
*8F pinnacle | *8F pinnacle | ||
*5F Pinnacle (for shuttle sheath not for access) | *5F Pinnacle (for shuttle sheath not for access) | ||
*110cm Shuttle sheaths (Size depends on occluder) | |||
*110cm Shuttle sheaths | *Agilis small curve | ||
====Standby==== | ====Standby==== | ||
*4fr x 10cm Pinnacle - (A-line) | *4fr x 10cm Pinnacle - (A-line) | ||
*Cook 30cm | *Cook 30cm | ||
*12F Dryseal | |||
===Wires:=== | ===Wires:=== | ||
| Line 45: | Line 47: | ||
====Open==== | ====Open==== | ||
* | *260 Standard J | ||
=== Standby wires: === | |||
*Straight Glide 260cm | *Straight Glide 260cm | ||
*Angled Glide 260cm | *Angled Glide 260cm | ||
*Amplatz ES 260cm | *Amplatz ES 260cm | ||
*.032 260J | *.032 260J | ||
| Line 56: | Line 60: | ||
*5F MPA 100 cm with a 125cm on standby | *5F MPA 100 cm with a 125cm on standby | ||
{{Note|The deployment cable for the ADO can be daisy-chained for more length!}} | {{Note|The deployment cable for the ADO can be daisy-chained for more length!}} | ||
| Line 71: | Line 73: | ||
*Baylis machine | *Baylis machine | ||
*Grounding pad | *Grounding pad | ||
* | *versacross | ||
===Device embolization / retrieval:=== | ===Device embolization / retrieval:=== | ||
Latest revision as of 05:56, 24 December 2025
Warning: This procedures equipment is highly variable, consult with the physician before opening expensive stuff.
Notes
- Various equipment needed is dependent upon size of leak.
- All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.
- Total Length of FlexCath: 81cm.
- Total Length of Agilis: 71cm
- If Flexcath is an acceptable option, use it. Much cheaper than agilis.
- AVPII cable length: 100cm Cables can be daisy-chained!
- 90cm Shuttle Sheath is not long enough to put into FlexCath. Will have to remove flex cath.
Misc Supplies:
Open
- 0-Ethibond
- Micropuncture
- Perclose
- 3-port manifold naked (no ACIST) - always open!
- 60cc syringe
Standby
- Watchdog
- stopcock
- Mustang for septostomy
- priority pack
- 180* torqvue (French size not important here, only using for the cable.)
Sheaths:
Open
- 8F pinnacle
- 5F Pinnacle (for shuttle sheath not for access)
- 110cm Shuttle sheaths (Size depends on occluder)
- Agilis small curve
Standby
- 4fr x 10cm Pinnacle - (A-line)
- Cook 30cm
- 12F Dryseal
Wires:
Open
- 260 Standard J
Standby wires:
- Straight Glide 260cm
- Angled Glide 260cm
- Amplatz ES 260cm
- .032 260J
Catheters:
Open
- 5F MPA 100 cm with a 125cm on standby
Note: The deployment cable for the ADO can be daisy-chained for more length!
Standby
- 5fr IM diagnostic
- 5fr JR4 diagnostic
- Berenstein 125cm (Spies)
Transseptal
Note: Not needed if recent transseptal procedure performed
Open
- Baylis machine
- Grounding pad
- versacross
Device embolization / retrieval:
Standby
- EnSnare or Gooseneck
- 16 or 18fr x 33cm Dryseal
- JR4 Guide