===Zeego===
===Zeego===


*<span class="s2"></span>Move c-arm to patient transport position before bringing any large equipment into the room.  
*Move c-arm to patient transport position before bringing any large equipment into the room.  
**<span class="s2"></span>Working position: table rotated 15*.
**Working position: table rotated 15*.
*<span class="s2"></span>If procedure requires TEE, have echo move into position before bringing c-arm in.
*If procedure requires TEE, have echo move into position before bringing c-arm in.
*<span class="s2"></span>Verify monitor elbow in correct position before draping.  See photo.
*Verify monitor elbow in correct position before draping.  See photo.


<br />
<br />
Line 18: Line 18:
===Storz Display===
===Storz Display===


*<span class="s2"></span>?VIntegration 2- Echo
*?VIntegration 2- Echo
*<span class="s2"></span>?VIntegration 1- Anesthesia Vitals
*?VIntegration 1- Anesthesia Vitals
*<span class="s2"></span>? Camera for monitor person
*?Camera for monitor person




Line 28: Line 28:
==ITEMS TO BRING:==
==ITEMS TO BRING:==


*<span class="s2"></span>TOGO Cart
*TOGO Cart
*<span class="s2"></span>Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
*Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
*<span class="s2"></span>Cath Packs
*Cath Packs
*<span class="s2"></span>Staff and MD Lead
*Staff and MD Lead
*<span class="s2"></span>Small table for defib
*Small table for defib
**<span class="s2"></span>may already be in OR14.  If not, check OR sterile core or sterile core behind lab 1
**may already be in OR14.  If not, check OR sterile core or sterile core behind lab 1


*<span class="s2"></span>Long scrub table from end of hall
*Long scrub table from end of hall
*<span class="s2"></span>Contrast- if needed
*Contrast- if needed




===MITRACLIP===
===MITRACLIP===


*<span class="s2"></span>Structural Cart
*Structural Cart
*<span class="s2"></span>Plug Cart
*Plug Cart
*<span class="s2"></span>Baylis
*Baylis
*<span class="s2"></span>Baylis Cable
*Baylis Cable
*<span class="s2"></span>Mitraclip guide and multiple of each size clip.
*Mitraclip guide and multiple of each size clip.
*<span class="s2"></span>Stabilizer
*Stabilizer
*<span class="s2"></span>Plexiglass and stabilizer lift
*Plexiglass and stabilizer lift
*<span class="s2"></span>IV Pole with at least (2) 1000 mL pressure bags.
*IV Pole with at least (2) 1000 mL pressure bags.
**<span class="s2"></span>may need a second pole and set of bags if it is known in advance a second clip is needed
**may need a second pole and set of bags if it is known in advance a second clip is needed
*<span class="s2"></span>Gel Pads
*Gel Pads
*<span class="s2"></span>Contrast attached to manifold if coronary angiogram to be performed
*Contrast attached to manifold if coronary angiogram to be performed


<br />
<br />
Line 57: Line 57:
===TAVR===
===TAVR===


*<span class="s2"></span>ACIST Setup
*ACIST Setup
*<span class="s2"></span>TAVR Cart
*TAVR Cart
*<span class="s2"></span>Structural Cart
*Structural Cart
*<span class="s2"></span>Plug Cart- can be parked outside the door
*Plug Cart- can be parked outside the door
*<span class="s2"></span>Delivery System and other vendor specific equipment from store room.
*Delivery System and other vendor specific equipment from store room.
*<span class="s2"></span>''Sentinel: Radial board and Verapamil''
*''Sentinel: Radial board and Verapamil''


<br />
<br />
Line 68: Line 68:
===TMVR===
===TMVR===


*<span class="s2"></span>Baylis
*Baylis
*<span class="s2"></span>Baylis Cable
*Baylis Cable
*<span class="s2"></span>TAVR Cart
*TAVR Cart
*<span class="s2"></span>Structural Cart
*Structural Cart
*<span class="s2"></span>Plug Cart
*Plug Cart
*<span class="s2"></span>Delivery system and other vendor specific equipment from store room
*Delivery system and other vendor specific equipment from store room
 
[[Category:Setups]]

Revision as of 20:32, 26 February 2020

Long table top for all procedures.  

Verify necessary ECMO equipment in OR sterile core Pyxis

Shield for Anesthesia


Zeego

  • Move c-arm to patient transport position before bringing any large equipment into the room.  
    • Working position: table rotated 15*.
  • If procedure requires TEE, have echo move into position before bringing c-arm in.
  • Verify monitor elbow in correct position before draping. See photo.


Storz Display

  • ?VIntegration 2- Echo
  • ?VIntegration 1- Anesthesia Vitals
  • ?Camera for monitor person



ITEMS TO BRING:

  • TOGO Cart
  • Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
  • Cath Packs
  • Staff and MD Lead
  • Small table for defib
    • may already be in OR14.  If not, check OR sterile core or sterile core behind lab 1
  • Long scrub table from end of hall
  • Contrast- if needed


MITRACLIP

  • Structural Cart
  • Plug Cart
  • Baylis
  • Baylis Cable
  • Mitraclip guide and multiple of each size clip.
  • Stabilizer
  • Plexiglass and stabilizer lift
  • IV Pole with at least (2) 1000 mL pressure bags.
    • may need a second pole and set of bags if it is known in advance a second clip is needed
  • Gel Pads
  • Contrast attached to manifold if coronary angiogram to be performed


TAVR

  • ACIST Setup
  • TAVR Cart
  • Structural Cart
  • Plug Cart- can be parked outside the door
  • Delivery System and other vendor specific equipment from store room.
  • Sentinel: Radial board and Verapamil


TMVR

  • Baylis
  • Baylis Cable
  • TAVR Cart
  • Structural Cart
  • Plug Cart
  • Delivery system and other vendor specific equipment from store room