Hybrid OR room 14: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
<br /> | <br /> | ||
=== | ===Zeego=== | ||
*<span class="s2"></span>Move c-arm to patient transport position before bringing any large equipment into the room. | *<span class="s2"></span>Move c-arm to patient transport position before bringing any large equipment into the room. | ||
Line 16: | Line 16: | ||
<br /> | <br /> | ||
=== | ===Storz Display=== | ||
*<span class="s2"></span>?VIntegration 2- Echo | *<span class="s2"></span>?VIntegration 2- Echo | ||
Line 26: | Line 26: | ||
<br /> | <br /> | ||
== | ==ITEMS TO BRING:== | ||
*<span class="s2"></span>TOGO Cart | *<span class="s2"></span>TOGO Cart | ||
Line 39: | Line 39: | ||
=== | ===MITRACLIP=== | ||
*<span class="s2"></span>Structural Cart | *<span class="s2"></span>Structural Cart | ||
Line 55: | Line 55: | ||
<br /> | <br /> | ||
=== | ===TAVR=== | ||
*<span class="s2"></span>ACIST Setup | *<span class="s2"></span>ACIST Setup | ||
Line 66: | Line 66: | ||
<br /> | <br /> | ||
=== | ===TMVR=== | ||
*<span class="s2"></span>Baylis | *<span class="s2"></span>Baylis |
Revision as of 20:26, 26 February 2020
Long table top for all procedures.
Verify necessary ECMO equipment in OR sterile core Pyxis
Shield for Anesthesia
Zeego
- Move c-arm to patient transport position before bringing any large equipment into the room.
- Working position: table rotated 15*.
- If procedure requires TEE, have echo move into position before bringing c-arm in.
- Verify monitor elbow in correct position before draping. See photo.
Storz Display
- ?VIntegration 2- Echo
- ?VIntegration 1- Anesthesia Vitals
- ? Camera for monitor person
ITEMS TO BRING:
- TOGO Cart
- Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
- Cath Packs
- Staff and MD Lead
- Small table for defib
- may already be in OR14. If not, check OR sterile core or sterile core behind lab 1
- Long scrub table from end of hall
- Contrast- if needed
MITRACLIP
- Structural Cart
- Plug Cart
- Baylis
- Baylis Cable
- Mitraclip guide and multiple of each size clip.
- Stabilizer
- Plexiglass and stabilizer lift
- IV Pole with at least (2) 1000 mL pressure bags.
- may need a second pole and set of bags if it is known in advance a second clip is needed
- Gel Pads
- Contrast attached to manifold if coronary angiogram to be performed
TAVR
- ACIST Setup
- TAVR Cart
- Structural Cart
- Plug Cart- can be parked outside the door
- Delivery System and other vendor specific equipment from store room.
- Sentinel: Radial board and Verapamil
TMVR
- Baylis
- Baylis Cable
- TAVR Cart
- Structural Cart
- Plug Cart
- Delivery system and other vendor specific equipment from store room