Septostomy: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 3: | Line 3: | ||
__TOC__ | __TOC__ | ||
An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left | An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated. | ||
ECHO guided transeptal puncture. | ECHO guided transeptal puncture. | ||
Line 16: | Line 16: | ||
*Cordis 260J | *Cordis 260J | ||
*5fr. MPA2 | *5fr. MPA2 | ||
*8.5fr. SL1 | *8.5fr. SL1 | ||
*Manifold to measure LA pressure | *Manifold to measure LA pressure |
Revision as of 18:34, 25 February 2020
An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated.
ECHO guided transeptal puncture.
Equipment:
Open
- Amplatz Super Stiff 1cm
- Cordis 260J
- 5fr. MPA2
- 8.5fr. SL1
- Manifold to measure LA pressure
- SHEATH*
Standby
- 0.32 x 260J
- Amplatz Extra Stiff
Baylis Setup:
Open
- Baylis generator
- Baylis Large curve needle
- Baylis cable
- Grounding Pad
Balloon size determined by MD.
*Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above.
Approved: MD initials MM/YY