An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrium pressures are high due to the Ecmo flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated.
Wires:
Open
- Amplatz Super Stiff 1cm tip
- Cordis 260J
Standby
- 0.32 x 260J
- Amplatz Extra Stiff
Catheters:
Open
- 6fr. MPA2
- 8.5fr. SL1
Baylis Setup:
Open
- Baylis generator
- Baylis Large curve needle
- Baylis cable
- Grounding Pad
Balloon:
Standby (ask)
- 20mm Tyshak Nucleus