Pulmonary Vein Angioplasty: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
==Baylis== | ==Baylis== | ||
===Open=== | ===Open=== | ||
*Baylis generator | *Baylis generator | ||
*Baylis cable | *Baylis cable | ||
Line 6: | Line 7: | ||
*SL1 transseptal sheath | *SL1 transseptal sheath | ||
*Grounding pad | *Grounding pad | ||
===Standby=== | ===Standby=== | ||
*ProTrack pigtail wire | *ProTrack pigtail wire | ||
*Baylis 8.5 transseptal sheath | *Baylis 8.5 transseptal sheath | ||
Line 12: | Line 15: | ||
==Ice== | ==Ice== | ||
===Open=== | ===Open=== | ||
*8fr AccuNav Ice catheter | *8fr AccuNav Ice catheter | ||
*SwiftLink cover | *SwiftLink cover | ||
Line 19: | Line 23: | ||
==Catheters== | ==Catheters== | ||
===Open=== | ===Open=== | ||
*5fr MPA2 diagnostic catheter | *5fr MPA2 diagnostic catheter | ||
===Standby=== | ===Standby=== | ||
*5fr angled pigtail | *5fr angled pigtail | ||
==Wires== | ==Wires== | ||
===Open=== | ===Open=== | ||
*Cordis 150J | *Cordis 150J | ||
*Amplatz Extra Stiff | *Amplatz Extra Stiff | ||
<br /> | |||
== Angioplasty == | |||
=== Standby === | |||
* 8, 9, 10 x 40 .035 balloons (ask for sizes) | |||
* Balloon expandable .035 stents (Ask for size) | |||
==Misc. Supplies== | ==Misc. Supplies== | ||
===Open=== | ===Open=== | ||
*Micropuncture | *Micropuncture | ||
*Probe cover | *Probe cover | ||
*Priority Pack | *Priority Pack | ||
*8fr x 10cm Pinnacle | *8fr x 10cm Pinnacle | ||
*0-Prolene suture (Spies) | |||
<br/> | |||
<hr/> | |||
Approved: MM/YY | |||
[[Category:Procedures]] |
Latest revision as of 20:54, 21 October 2019
Baylis
Open
- Baylis generator
- Baylis cable
- Baylis Large Curve C1 needle
- SL1 transseptal sheath
- Grounding pad
Standby
- ProTrack pigtail wire
- Baylis 8.5 transseptal sheath
Ice
Open
- 8fr AccuNav Ice catheter
- SwiftLink cover
- 9fr x 23cm Pinnacle
- Sequoia Ultrasound machine from EP (Can also be used for access - 9L probe)
Catheters
Open
- 5fr MPA2 diagnostic catheter
Standby
- 5fr angled pigtail
Wires
Open
- Cordis 150J
- Amplatz Extra Stiff
Angioplasty
Standby
- 8, 9, 10 x 40 .035 balloons (ask for sizes)
- Balloon expandable .035 stents (Ask for size)
Misc. Supplies
Open
- Micropuncture
- Probe cover
- Priority Pack
- 8fr x 10cm Pinnacle
- 0-Prolene suture (Spies)
Approved: MM/YY