Revision as of 19:50, 16 October 2019
Daniels/Spies - Draft
Also used for Dr. Sheridan
Wires:
Open
- Supracore 190
- Cordis 150J
Standby
- Amplatz Extra Stiff
- Glidewire
Sheaths:
Open
- 8fr Pinnacle
ECMO cart:
Open
- ECMO instruments
- 16/18 Coons dilators
- 20/22 Coons Dilators
- Arterial vented cannula - Normally 16fr.
- Venous cannula - Normally 21fr.
- Irrigation bulb syringe
- ”Carrot tops” Orange vessel tourniquets
Standby
- Alternative sizes of cannulas
- Arrow 5 and 6fr braided sheaths for antegrade bypass
- Male Male luer adapter for antegrade bypass
Misc Supplies:
Open
- Micropuncture
- Probe cover
- 25g lido needle (Daniels)
- (2) Perclose
- (2) 0 Silk or Ethibond (Not for Sheridan)
- (2) 2-0 Prolene (Open 4 for Dr. Sheridan)
- (2) “Suture Locks”
- (2) Biopatch
Egrie
- Substitute Vascular dilator kit for Coons dilators
- Substitute white nylon and Martin free needles for securement suture