DRAFT
Device:
Standby
- Toray INOUE-Balloon Kit (usually 28 mm, but need 26 and 30 mm available)
Sheaths:
Open
- 9frx20 Brite tip
- 8frx10 Pinnacle
- 8.5 SL1 transseptal
Wires:
Open
- Amplatz Super Stiff 260cm 1cm tip
- Cordis 150J
Standby
- .032 wire for SL1 sheath
Catheters:
Open
- 5fr MPA2
Baylis/TransSeptal:
Open
- Baylis generator from EP
- Large curve C1 Baylis needle
- Baylis cable
- Grounding pad
Misc Supplies:
Open
- Micropuncture
- US probe cover
- (2) 3-port manifolds
- Closure
- 0-Prolene or 0-PDSII (Spies)
- Perclose (Not Spies)
- 25g blue lido needle (Daniels)
- 60cc syringe
- Stopcock
Pericardiocentesis (Standby):
Not DD or CS
Call Echo
- Micropuncture
- 75 Amplatz SS
- Pericardiocentesis tray
- Accordion drain bag
Spies
Call Echo
Supplies:
- Micro puncture
- 150cm J wire
- 4/5fr slender sheath
- 5fr straight pigtail diagnostic
- gravity drainage bag
- brown reservoir lab canister
- Two 50 or 60ml syringes
Daniels
Call Echo
Supplies
Open
Emergency Kit located in each lab containing the following items:
- Eye drape
- Skater introducer set
- Bard locking pigtail (6f or 8f)
- (3) 60ml luer lock syringe
- Amplatz super stiff .035 180cm wire
- Probe cover
- Stopcock
- Accordion drainage bag
Standby
- Chiba biopsy needle 10cm 18g
- Standard .035 150cm j wire
Emergency Standby:
- IABP
APPROVED: MD initials MM/YY