Setup

  • Obtain height, weight, blood pressure on all patients
  • Obtain ECG tracing
    • 3 beat loop
      • If HR > 100 bpm increase number of loops to 4 beats
      • If HR > 120 bpm increase number of loops to 5 beats

Note Warning: DO NOT ACQUIRE IMAGES WITHOUT AN ADEQUATE ECG TRACING

View Modality Image #beats
1 Patient information page
PARASTERNAL LONG AXIS
2 2D PLAX depth 5 cm (adequate to visualize pericardial/pleural effusion or 3
3 2D PLAX depth 2 cm (on axis for LV, measure EF) 3
4 Color Mitral and aortic valve 3
5 2D AoV (Zoom; optimize for LVOT measurement; should include both Ao root sinuses) 3 x2
6 2D RV inflow- TV 3
7 Color RV inflow- TV with color 3
8 CW RV inflow- TR jet 3
9 2D RV outflow PV 3
10 Color RV outflow PV (focus on RVOT) 3
PARASTERNAL SHORT AXIS
11 2D AoV level, show TV, PV and left atrium 3
12 2D Tricuspid valve 3
13 Color TV, TR jet 3
15 CW TR jet 3
16 Color Color on Occluder (if ASD/PFO closure)
17 2D Mid-pap level
Apical 4-Chamber View
18 2D Apical 4-Chamber (all 4 chambers) 3
19 2D Apical 4-Chamber (LV focused- for biplane Simpson’s & RWMA) 3 x2
20 2D Apical 4-Chamber Simpsons measurement
21 2D LA measurement
22 Color MV inflow Color 3
23 2D Apical 4-Chamber LAA focused (If for LAAO)
24 Color Apical 4 Chamber LAA focused color sweep (Nyquist <50 cm/s, increase color gain) 3
25 2D RA measurement
26 2D RV focused View 3
27 Color RV focused (TV and TR jet) 3
28 CW RV focused (TV and TR jet) 3
Apical 5-Chamber View
29 2D Apical 5-Chamber (all 5 chambers) 3
30 Color Apical 5-Chamber (color box to display complete AR jet) 3
31 PW Apical 5-Chamber PW of LVOT, optimize baseline 3
32 CW Apical 5-Chamber AV CW 3
Apical 2-Chamber View
33 2D Apical 2-Chamber 3 x2
34 2D Apical 2-Chamber Simpsons measurement
35 Color Apical 2-Chamber focus on MV color 3
36 2D LA measurement
37 2D Apical 2-Chamber LAA focused (if for LAAO)
38 Color Apical 2-Chamber LAAO focused color sweep (Nyquist <50cm/s, increase color gain)
Apical 3-Chamber View
39 2D Apical 3-Chamber (all 3 chambers) 3
40 Color Apical 3-Chamber (color box to display complete AR jet) 3
41 Color Apical 3-chamber color MV
Subcostal
42 2D Subcostal, 4-chamber
43 2D Interatrial septum (zoom)
44 Color Interatrial septum (zoom) Color Nyquist <50 cm/s (on device if applicable) 3 x2
45 2D IVC and measurement
46* Color IVC and hepatic vein
PISA- please consider for moderate or greater regurgitation; aliasing velocity 30-38 cm/s
3D & 3D color- feel free to acquire; single beat and multi-beat acquisitions
Anything more than mild valve disease use 3D protocol