Hybrid OR room 14: Difference between revisions

From Bay Area Structural Heart Wiki
Dronsfj (talk | contribs)
No edit summary
 
(6 intermediate revisions by 3 users not shown)
Line 5: Line 5:
'''Shield for Anesthesia'''
'''Shield for Anesthesia'''


<br />


==='''Zeego'''===
===Zeego===


*<span class="s2"></span>Move c-arm to patient transport position before bringing any large equipment into the room.  
*Move c-arm to patient transport position before bringing any large equipment into the room.  
**<span class="s2"></span>Working position: table rotated 15*.
**Working position: table rotated 15*.
*<span class="s2"></span>If procedure requires TEE, have echo move into position before bringing c-arm in.
*If procedure requires TEE, have echo move into position before bringing c-arm in.
*Verify monitor elbow in correct position before draping.


<br />
===Storz Display===


==='''Storz Display'''===
*VIntegration 2- Echo
*VIntegration 1- Anesthesia Vitals
*Camera for monitor person


*<span class="s2"></span>?VIntegration 2- Echo
==ITEMS TO BRING:==
*<span class="s2"></span>?VIntegration 1- Anesthesia Vitals
*<span class="s2"></span>? Camera for monitor person


*TO GO Cart
*Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
*Cath Packs
*Staff and MD Lead


*Long scrub table from end of hall
*Contrast


<br />


=='''ITEMS TO BRING:'''==
===MITRACLIP===


*<span class="s2"></span>TOGO Cart
*Structural Cart
*<span class="s2"></span>Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
*Plug Cart
*<span class="s2"></span>Cath Packs
*Baylis
*<span class="s2"></span>Staff and MD Lead
*Baylis Cable
*<span class="s2"></span>Small table for defib
*Mitraclip guide and multiple of each size clip.
**<span class="s2"></span>may already be in OR14.  If not, check OR sterile core or sterile core behind lab 1
*Stabilizer
*Plexiglass and stabilizer lift
*IV Pole with at least (2) 1000 mL pressure bags.
**may need a second pole and set of bags if it is known in advance a second clip is needed
*Gel Pads
*Contrast attached to manifold if coronary angiogram to be performed


*<span class="s2"></span>Long scrub table from end of hall
*<span class="s2"></span>Contrast- if needed


===TAVR===


==='''MITRACLIP'''===
*ACIST Setup
*TAVR Cart
*Structural Cart
*Plug Cart- can be parked outside the door
*Delivery System and other vendor specific equipment from store room.
*''Sentinel: Radial board and Verapamil''


*<span class="s2"></span>Structural Cart
===TMVR===
*<span class="s2"></span>Plug Cart
*<span class="s2"></span>Baylis
*<span class="s2"></span>Baylis Cable
*<span class="s2"></span>Mitraclip guide and multiple of each size clip.
*<span class="s2"></span>Stabilizer
*<span class="s2"></span>Plexiglass and stabilizer lift
*<span class="s2"></span>IV Pole with at least (2) 1000 mL pressure bags.
**<span class="s2"></span>may need a second pole and set of bags if it is known in advance a second clip is needed
*<span class="s2"></span>Gel Pads
*<span class="s2"></span>Contrast attached to manifold if coronary angiogram to be performed


<br />
*Baylis
*Baylis Cable
*TAVR Cart
*Structural Cart
*Plug Cart
*Delivery system and other vendor specific equipment from store room


==='''TAVR'''===
[[Category:Setups]]
 
*<span class="s2"></span>ACIST Setup
*<span class="s2"></span>TAVR Cart
*<span class="s2"></span>Structural Cart
*<span class="s2"></span>Plug Cart- can be parked outside the door
*<span class="s2"></span>Delivery System and other vendor specific equipment from store room.
*<span class="s2"></span>''Sentinel: Radial board and Verapamil''
 
<br />
 
==='''TMVR'''===
 
*<span class="s2"></span>Baylis
*<span class="s2"></span>Baylis Cable
*<span class="s2"></span>TAVR Cart
*<span class="s2"></span>Structural Cart
*<span class="s2"></span>Plug Cart
*<span class="s2"></span>Delivery system and other vendor specific equipment from store room

Latest revision as of 21:34, 7 January 2025

Long table top for all procedures.  

Verify necessary ECMO equipment in OR sterile core Pyxis

Shield for Anesthesia


Zeego

  • Move c-arm to patient transport position before bringing any large equipment into the room.  
    • Working position: table rotated 15*.
  • If procedure requires TEE, have echo move into position before bringing c-arm in.
  • Verify monitor elbow in correct position before draping.

Storz Display

  • VIntegration 2- Echo
  • VIntegration 1- Anesthesia Vitals
  • Camera for monitor person

ITEMS TO BRING:

  • TO GO Cart
  • Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
  • Cath Packs
  • Staff and MD Lead
  • Long scrub table from end of hall
  • Contrast


MITRACLIP

  • Structural Cart
  • Plug Cart
  • Baylis
  • Baylis Cable
  • Mitraclip guide and multiple of each size clip.
  • Stabilizer
  • Plexiglass and stabilizer lift
  • IV Pole with at least (2) 1000 mL pressure bags.
    • may need a second pole and set of bags if it is known in advance a second clip is needed
  • Gel Pads
  • Contrast attached to manifold if coronary angiogram to be performed


TAVR

  • ACIST Setup
  • TAVR Cart
  • Structural Cart
  • Plug Cart- can be parked outside the door
  • Delivery System and other vendor specific equipment from store room.
  • Sentinel: Radial board and Verapamil

TMVR

  • Baylis
  • Baylis Cable
  • TAVR Cart
  • Structural Cart
  • Plug Cart
  • Delivery system and other vendor specific equipment from store room